Login
Registrati
Reimposta password
Pubblica & Distribuisci
Soluzioni Editoriali
Soluzioni di Distribuzione
Temi
Architettura e design
Arti
Business e Economia
Chimica
Chimica industriale
Farmacia
Filosofia
Fisica
Geoscienze
Ingegneria
Interesse generale
Legge
Letteratura
Linguistica e semiotica
Matematica
Medicina
Musica
Scienze bibliotecarie e dell'informazione, studi library
Scienze dei materiali
Scienze della vita
Scienze informatiche
Scienze sociali
Sport e tempo libero
Storia
Studi classici e del Vicino Oriente antico
Studi culturali
Studi ebraici
Teologia e religione
Pubblicazioni
Riviste
Libri
Atti
Editori
Blog
Contatti
Cerca
EUR
USD
GBP
Italiano
English
Deutsch
Polski
Español
Français
Italiano
Carrello
Home
Riviste
Journal of Electrical Bioimpedance
Volume 5 (2014): Numero 1 (January 2014)
Accesso libero
Simplified estimation of membrane potentials induced by high-frequency electric signals
Mehrdad Saviz
Mehrdad Saviz
e
Reza Faraji-Dana
Reza Faraji-Dana
| 31 dic 2014
Journal of Electrical Bioimpedance
Volume 5 (2014): Numero 1 (January 2014)
INFORMAZIONI SU QUESTO ARTICOLO
Articolo precedente
Articolo Successivo
Sommario
Articolo
Immagini e tabelle
Bibliografia
Autori
Articoli in questo Numero
Anteprima
PDF
Cita
CONDIVIDI
Article Category:
Articles
Pubblicato online:
31 dic 2014
Pagine:
9 - 13
Ricevuto:
03 lug 2013
DOI:
https://doi.org/10.5617/jeb.738
Parole chiave
Cytoplasm Membranes
,
Numerical Modeling
,
Trans-membrane Potential
,
High Frequencies
© 2014 Mehrdad Saviz and Reza Faraji-Dana, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Fig.1
Models for field distribution with and without membranes: (a) The case where the electric field is perpendicular to the membrane; (b) The case where the electric field is parallel to the membrane.
Fig.2
The electrical properties of the aqueous phase: solid line: real permittivity, dash-dotted line: effective conductivity.
Fig.3
Log plot for the difference of the admittance ratio M from unity, which shows that approximately from f=100 MHz onwards, the presence of membrane becomes insignificant in the overall admittance.
Fig.4
Membrane amplification factor G. The first drop occurs when displacement currents become dominant. The second drop occurs due to water relaxation around 20 GHz.
Fig.5
Potential distribution with the presence of membranes, and normal electric field in the membrane (along the dashed curve in the cell membrane); solid line: results of removing membranes in the numerical model and retrieval of membrane fields using (Eq.6), Markers: exact numerical computation of membrane fields, for (a) 1MHz, (b) 1GHz, (c) 500 GHz.