Accès libre

The Determination of the Water Content in Cigarette Smoke Condensate Using a Karl Fischer Titrator / Wasserbestimmung im Rauchkondensat nach Karl Fischer mit einer halbautomatischen Apparatur

   | 03 juil. 2014
À propos de cet article

Citez

The current method of determination of the water content of cigarette smoke condensate was improved by using a Karl Fischer titrator with automatic end-point stop. The overall procedure thus becomes faster (the titration time is less than 2 minutes), easier (no supervision is needed during the titration) and better reproducible (coefficient of variation 2.5 % on the amount of water determined). In these three criterions, the automated Karl Fischer method is superior to a gas-chromatographic procedure having served as a method of comparison.

eISSN:
1612-9237
Langue:
Anglais
Périodicité:
4 fois par an
Sujets de la revue:
General Interest, Life Sciences, other, Physics