Iniciar sesión
Registrarse
Restablecer contraseña
Publicar y Distribuir
Soluciones de Publicación
Soluciones de Distribución
Temas
Arquitectura y diseño
Artes
Ciencias Sociales
Ciencias de la Información y Bibliotecas, Estudios del Libro
Ciencias de la vida
Ciencias de los materiales
Deporte y tiempo libre
Estudios clásicos y del Cercano Oriente antiguo
Estudios culturales
Estudios judíos
Farmacia
Filosofía
Física
Geociencias
Historia
Informática
Ingeniería
Interés general
Ley
Lingüística y semiótica
Literatura
Matemáticas
Medicina
Música
Negocios y Economía
Química
Química industrial
Teología y religión
Publicaciones
Revistas
Libros
Actas
Editoriales
Blog
Contacto
Buscar
EUR
USD
GBP
Español
English
Deutsch
Polski
Español
Français
Italiano
Carrito
Home
Revistas
Journal of Electrical Bioimpedance
Volumen 6 (2015): Edición 1 (January 2015)
Acceso abierto
Sources of error in AC measurement of skin conductance
Ørjan G.Martinsen
Ørjan G.Martinsen
,
Oliver Pabst
Oliver Pabst
,
Christian Tronstad
Christian Tronstad
y
Sverre Grimnes
Sverre Grimnes
| 29 dic 2015
Journal of Electrical Bioimpedance
Volumen 6 (2015): Edición 1 (January 2015)
Acerca de este artículo
Artículo anterior
Artículo siguiente
Resumen
Artículo
Figuras y tablas
Referencias
Autores
Artículos en este número
Vista previa
PDF
Cite
Compartir
Article Category:
Articles
Publicado en línea:
29 dic 2015
Páginas:
49 - 53
Recibido:
08 dic 2015
DOI:
https://doi.org/10.5617/jeb.2640
Palabras clave
Electrodermal activity
,
galvanic skin response
,
skin conductance
,
bioimpedance
© 2015 Ørjan G. Martinsen, Oliver Pabst, Christian Tronstad, Sverre Grimnes, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Figure 1
Electrical model of skin
Figure 2
Conductance G and Susceptance B (150 mV rms) as a function of frequency for two palmar Kandall KittyCat® electrodes. The measurements are done for two different levels of sweat activity. Average and standard deviation of 20 measurements for each of the two levels.
Figure 3
Simultaneous measurement of AC conductance and susceptance (20 Hz, 500 mV peak amplitude) and DC conductance (500 mV) on the right palmar skin site during excitation (combing through the test subject’s hair). These measurements are done in parallel to the measurements shown in figure 2. It shows the test subject’s EDA during the whole session (20 frequency scans).
Figure 4
Simultaneous measurement of AC conductance and susceptance (20 Hz, 500 mV peak amplitude) and DC conductance (500 mV) on the right palmar skin site during relaxation. These measurements are done in parallel to the measurements shown in figure 2. It shows the test subject’s EDA during the whole session (20 frequency scans).
Figure 5
The three-electrode electrical admittance measuring system, showing measuring (M), reference (R) and current carrying (C) electrodes on the skin (left) and with skin impedance and DC potential (right).
Figure 6
Examples of simultaneously measured skin potential and conductance. From [3] with permission. Top: Highly correlated potential and conductance curves. Bottom: Example of biphasic potential curves.
Figure 7
Skin surface conductance density at 22 Hz measured with Kendall Kittycat® solid hydrogel electrode (A) and Ambu Blue Sensor® Q-00-A wet gel electrode (B) on hypothenar skin sites. From [14]. © Institute of Physics and Engineering in Medicine. Reproduced by permission of IOP Publishing. All rights reserved.
Figure 8
Skin surface conductance density at 22 Hz measured with Kendall Kittycat® solid hydrogel electrode (A) and Ambu Blue Sensor® Q-00-A wet gel electrode (B) on the abdomen. From [14]. © Institute of Physics and Engineering in Medicine. Reproduced by permission of IOP Publishing. All rights reserved.
Vista previa