Diurnal variations in streamflow (DVS) have been studied in detail by underwater pressure loggers. Some of this equipment requires barometric compensation with a logger or sensor located outside the water. Studies related to this topic have not offered a critical report of the validity of patterns inferred with these instruments. While studying a forested watershed in Southern Chile (40° S), we detected a DVS when the external logger was placed 1.5 m above ground, under a marked diurnal fluctuation in air temperature (amplitude 12.4 °C) and a dampened fluctuation in stream temperature (amplitude 1.4 °C). Synchronization was apparent between air and stream temperature in a direct relationship, but the synchronization between air/stream temperature and streamflow was negative, with some hours of lag time. In laboratory experiments, when the external logger is considerably warmer than the water-level logger, depth measurements can be underestimated by up to 1.5 cm. When the opposite occurs, water depths can be overestimated by up to 0.9 cm and are large instrumental/methodological artifacts compared to the field water diurnal variation of 1.3 cm. Finally, we relocated the external logger in front of the water-level logger and inside a weir, but exposed to the air. Results confirmed the pattern previously detected in the field, but streamflow fluctuations were 19% less accentuated. We conclude that the incorrect placement of the external logger, along with an instrumental artifact, can intensify a DVS pattern.