[Bayouth JE, Wendt D, Morrill SM. MLC quality assurance technique for IMRT applications. Med Phys. 2003; 30(5): 743-750.10.1118/1.1564091]Search in Google Scholar
[Bohsung J, Groll J, Moys A, Bohmer D, Marnitz S, Budach V. One year of clinical IMRT with dynamic MLC - the Charite experience from a physicist point of view. Proceedings of the 9th Varian European Users Meeting; 2001: 39-45.]Search in Google Scholar
[Chui C-S, Spirou S, LoSasso T. Testing of dynamic multileaf collimation. Med Phys. 1996; 23(5): 635-641.10.1118/1.597699]Search in Google Scholar
[Deshpande D D, Kinhikar R A, Sherly S, Ghosh S, Srivastava S K, Dinshaw K A. Quality Assurance (QA) and implementation of intensity modulated radiotherapy (IMRT) with dynamic multileaf collimator (DMLC) on 2100 C/D linear Accelerator. J Med Phys. 2002; 27(2): 41-50.]Search in Google Scholar
[Dinesh Kumar M, Thirmavalavan N, Venugopal Krishna D, Babaiah M. QA of intensity modulation beams using dynamic MLC log files. J Med Phys. 2006; 31(1): 36-41.10.4103/0971-6203.25668]Search in Google Scholar
[Essers M, de Langen M, Dirkx MLP, Heijmen BJM. Commissioning of a commercially available system for intensity-modulated radiotherapy dose delivery with dynamic multileaf collimation. Radiother Oncol. 2001; 60: 215-224.10.1016/S0167-8140(01)00317-6]Search in Google Scholar
[Gary A. Ezzell, Jay W. Burmeister, Nesrin Dogan, Thomas J. LoSasso, James G. Mechalakos and Dimitris Mihailidis et al. IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys. 2009; 36(11): 5359-5373.10.1118/1.3238104]Search in Google Scholar
[Intensity Modulated Radiation Therapy Collaborative Working Group, Intensity-modulated radiotherapy: Current status and issues of interes. Int J Radiat Oncol Biol Phys. 2001; 51(4): 880-914.10.1016/S0360-3016(01)01749-7]Search in Google Scholar
[Kallman P, Lind B, Eklof A, Brahme A. Shaping of arbitrary dose distribution by dynamic multileaf collimation. Phys Med Biol. 1998; 33: 1291-1300.10.1088/0031-9155/33/11/0073231672]Search in Google Scholar
[Klein EE, Hanley J, Bayouth J, Yin FF, Simon W and Dresser S et al. Task Group 142 report: quality assurance of medical accelerators Med Phys. 2009; 36(9): 4197-212.10.1118/1.319039219810494]Search in Google Scholar
[LoSasso T, Chui C-S, Ling C. Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. Med Phys. 1998; 25(10): 1919-1927.10.1118/1.5983819800699]Search in Google Scholar
[LoSasso T, Chui C-S, Ling C. Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic mode. Med Phys. 2001; 28(11): 2209-2219.10.1118/1.141012311764024]Search in Google Scholar
[Palta JR, Liu C, Li JG. Quality assurance of intensity modulated radiation therapy. Int J Radiat Oncol Biol Phys. 2008; 71(1 Suppl): S108-12.10.1016/j.ijrobp.2007.05.092]Search in Google Scholar
[Ravichandran R, Binukumar J P, Sivakumar S S, Krishnamurthy K, Davis C A. A method for estimation of accuracy of dose delivery with dynamic slit windows in medical linear accelerators. J Med Phys. 2008; 33(3): 127-129.10.4103/0971-6203.42768]Search in Google Scholar
[Sivakumar S S, Krishnamurthy K, Davis, R Ravichandran C A, Kannadhasan S, Binukumar J P, Kamal EI Ghamrawy. Clinical implementation of dynamic intensity modulated radiotherapy: Dosimetric aspects and initial experience. J Med Phys. 2008; 33(2): 64-71.10.4103/0971-6203.41195]Search in Google Scholar
[Van Esch A, Bohsung J, Sorvari P, et al. Acceptance test and quality control (QC) procedures for the clinical implementation of intensity modulated radiotherapy (IMRT) using inverse planning and sliding window technique: Experience from five radiotherapy departments. Radiother Oncol. 2002; 60: 53-70.10.1016/S0167-8140(02)00174-3]Search in Google Scholar