Open Access

Causes of differences in the uptake of cardiac implantation electronic devices in Slovenia in comparison to other countries


Cite

Figure 1

Crude utilisation rates of PMs and ICDs in 2011, in 5 European countries according to age group, gender and country.
Crude utilisation rates of PMs and ICDs in 2011, in 5 European countries according to age group, gender and country.

Comparison of the data on numbers of PMs and ICDs from national hospital discharge database with the data published in the European Heart Rhythm Association (EHRA) of the European Society of Cardiology (ESC).

SloveniaAustriaAll UK EnglandGermanyItaly
YearEHRAHospitalsDiffEHRAHospitalsDiffEHRAHospitalsDiffEHRAHospitalsDiffEHRAHospitalsDiff
Pacemakers
20081100586-88%757076902%4057037734-8%9830089194-10%61300622202%
2009935652-43%79307500-6%39850427017%10217792215-11%6300062215-1%
20101153602-92%77127589-2%371944563618%10342394659-9%6340062202-2%
20111295604-114%781078701%382395054024%10695396013-11%6310062141-2%
20121333667-100%787079501%38770010656796403-11%61300620981%
ICDs
2008961037%110011040%74035086-46%2160020948-3%1800016554-8%
200911114523%12901157-11%507753766%2357422940-3%105001510030%
201010117643%12681176-8%517553443%2507124422-3%111001393320%
201114417417%18051195-51%540454671%2657925219-5%119701410615%
201212219638%119512968%576202653625956-2%120001394314%

Charlson Comorbidity Index – average of weighted CCI scores for each category of device, by country for the year 2011.

AustriaEnglandGermanyItalySlovenia
Overall CCI scores
PM implants0.100.901.630.961.07
ICD implants0.581.322.501.271.52
PM implantsAcute myocardial infarction (AMI)1%1%9%5%6%
Congestive Heart Failure4%15%32%13%23%
DiabetesN/A17%20%11%22%
ICD implantsAMI2%5%35%14%26%
Congestive Heart Failure54%60%91%73%63%
Diabetes0%20%25%13%16%

Main reasons for difference in data in CIEDs uptake in 5 European countries (2008-2012).

The reason for the difference in the dataA description
The use of Australian coding system valid until 21 December in Slovenia

No codes for PM replacement

Some codes were valid only until 31 December 2010

Not specific enough (no codes for single chamber, dual chamber, BV/CRT, CRT_P or CRT_D procedures)

Only a partial link between financing and DRG coding in Slovenia

In Slovenia, coding is considered as an additional administrative burden

No golden rule for the optimal crude utilisation rate

In Slovenia, an absolute indication is needed to receive the implant

Variations in relative indications, financial restrictions and other contextual factors across countries

Differences in political priorities

Different economic developments across countries

Differences in decision-making rules on including health care programmes in the basic benefit package

Main reasons for difference in PM and ICD implants crude utilization rate (number of devices/100.000 inhabitants) across 5 European countries, 2008-2012.

Pacemaker implants
AustriaEnglandGermanyItalySlovenia
200867.360.087.274.329.9
200966.568.990.674.632.7
201070.575.794.575.131.2
201171.084.196.075.829.7
201272.4N/A96.477.632.7
AGR

average growth rate

1.8411.912.541.092.26
eISSN:
1854-2476
Language:
English
Publication timeframe:
4 times per year
Journal Subjects:
Medicine, Clinical Medicine, Hygiene and Environmental Medicine