Open Access

Numerical Comparison of Thermal Behaviour Between Ventilated Facades


Cite

Increasingly high demands on environmental protection are intensifying the development of sustainable construction. Ventilated facades can provide an energy-efficient alternative to standard facades, that is, external thermal insulation composite systems (ETICS). The article compares standard facades, which was a reference, to ventilated facades in two variants: closed joints and open joints. The comparison was made by means of numerical simulations of computational fluid dynamic (CFD), under conditions of high outside temperature and high sunshine. The results showed great benefits of using ventilated facades in such external climate conditions. It was also observed that the selection of the variant of ventilated facade in the system of close or open joints has minimal influence on thermal efficiency of the whole partition.

eISSN:
2083-831X
Language:
English
Publication timeframe:
4 times per year
Journal Subjects:
Geosciences, other, Materials Sciences, Composites, Porous Materials, Physics, Mechanics and Fluid Dynamics