In reinforced concrete grain silos, the emptying phase entails time-variable static and dynamic impacts from the pressure of the bulk solid, which cause complex stress states and major deformations in the concrete wall and the bottom structures. Especially in the case of non-centric emptying on large eccentricities (when the discharge eccentric is larger than half of the radius), the non-symmetrical pressure wave distributions in the silo chamber in the bulk solid flow zone and on the chamber perimeter are not fully recognised. The effect of non-symmetrical interactions in silos is eccentric tension or compression, which contributes to increased local effort and cracks on reinforced concrete walls and, in some cases, may even lead to silo failure. These are important issues in the field of mechanics of engineering structures made of concrete.
The in situ research on exploited objects [1, 2, 3] and silo models [4], as well as theoretical research [5, 6], confirms the occurrence of randomly variable pressure distributions in the silo as a result of eccentric emptying. Analysis of silo failure and disasters [7, 8] shows that one of the main causes of failure of these structures, which are designed to be used for at least 100 years [9], is incorrect assumptions regarding the calculation of loads. The results of experimental and theoretical research are applied to improve and expand the methods for determining the impact of bulk solid recommended in the norms [10, 11] and guidelines [12] for the design of silo structures.
To take into account the degree of uncertainty in relation to the accurate determination of the load value, Eurocode 1, Part 4 [11] divides silos into three action assessment classes (AACs; Table 1). Assigning the appropriate class to a silo entails application of simplified or expanded procedures for determining the component values of bulk solid pressure [11, 13]. This initiated extended proceedings for determining the interactions in silos of large mass bulk solid storage and in silos that are filled or emptied on large eccentricities (category AAC3 and category AAC2, respectively). Silos in which the mass of stored material is >1,000 tons and is disposed of in large eccentricities (
Classification of silo action assessment class according to - Eurocode 1, Part 4 [11].
Action assessment class | Class description |
---|---|
Action assessment class 3 (AAC3) | Silo with storage volume of >10,000 tons. |
Silo with storage volume of >1,000 tons, with any of the following calculation situations: | |
a) non-centric emptying at | |
b) low silos, with the eccentricity of the upper filling cone | |
Action assessment class 2 (AAC2) | All silos mentioned in Eurocode 1, Part 4 [11] which are not assigned to a different class. |
Action assessment class 1 (AAC1) | Silo with storage volume of <100 tons. |
For the example of reinforced concrete cylindrical wheat silo with a diameter of 10 m and a chamber height of 25 m, emptied non-centrically and classified as AAC3, the influence of the flow channel radius on the redistribution of stresses in reinforced concrete cross-sections of the silo chamber is presented.
In slender silos emptied on large eccentricities (
1) Increased local pressure (patch load), which is variantly applied at any height (in other zones, there are symmetrical pressures), as shown in Fig. 1.
Increased local pressure (patch load) directed towards the outside of the silo (Fig. 1) is determined based on the following formula:
where
Similarly, the component of the local pressure directed inside the silo chamber and operating on the remaining part of the silo’s perimeter (Fig. 1) is calculated based on the following formula:
2) Pressure, taking into account the geometry of the flow channel (Fig. 2).
Components of pressure in a horizontal cross-section of the ACC3 class silo chamber (Fig. 2), according to Eurocode 1, Part 4 [11], are calculated based on the following formula:
where
The values of surface friction against the wall are calculated based on the following relation:
where
The geometry of the loose material flow channel in the silo depends on the dimensions of the silo structure and on random parameters, such as variable properties of loose material stored in the silo, uncertainty of the type of flow and the time variability of the pressure distribution on the wall perimeter during emptying. According to Eurocode 1, Part 4 [11], the angle length of the segment where the wall touches the flow channel in the flow zone of the bulk solid is calculated based on the following relation:
where
The eccentric of the flow channel can be determined based on the following expression:
where
When applying the above relations, it is necessary to once again calculate the parameters determining the geometry of the flow channel each time the radius of the silo is changed. The Eq. (5) for determining the value of cos
Application of Eq. (7), proposed by the authors, at the stage of silo design considerably accelerates and facilitates determination of the distribution of the pressure of the bulk solid in the silo in the case of eccentric emptying on large eccentricities [14]. Table 2 presents the calculated angle values for the selected bulk solids.
Parameters specifying the geometry of the flow channel (AAC3 class) for the selected bulk solids for reinforced concrete silo wall (D3 wall category, according to Eurocode 1, Part 4 [11]).
Type of bulk solid | μ | μ | μ/tan | ec/r | Angle θ | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Barley | 0.48 | 1.16 | 0.410 | 28 | 1.14 | 31.92 | 0.658 | 0.790 | 0.660 | 0.479 | 8.9 | 14.8 | 24.9 |
Corn | 0.53 | 1.12 | 0.470 | 31 | 1.14 | 35.34 | 0.663 | 0.789 | 0.659 | 0.478 | 8.5 | 14.8 | 24.8 |
Wheat | 0.57 | 1.16 | 0.490 | 30 | 1.12 | 33.6 | 0.738 | 0.780 | 0.646 | 0.461 | 7.7 | 13.3 | 22.3 |
By applying the relations represented in Eqs. (3) and (7), the authors determined the values and distributions of wheat pressure in the silo chamber during eccentric emptying for different values of the radius of the flow channel (Fig. 3), adopted in the numerical analysis of the considered silo.
To carry out the analysis of internal forces in the silo chamber wall, the authors created a 3D model of a free-standing silo with height
The walls of the silo chamber were modelled in the form of 13 rings with the heights ranging from 2 to 2.375 m. In the programme, a net was generated with mesh dimensions of 0.40 × 1.31 m. The obtained net was thickened twice at the height of the silo in the area of the appearing local pressure, in the zone of occurrence of the flow channel as well as at the place of connection of the wall with the foundation and the bottom plate of the silo. Data on discretisation of the calculation model of the grain silo is presented in Table 3.
Data on discretisation of the silo model (finite element method).
Number of elements (panels) | 15 (13 wall panels, 1 bottom plate panel, 1 cover plate panel) |
Number of distribution nodes | 4,030 |
Standard net dimensions | 40 cm × 131 cm |
Thickened net dimensions | 20 cm × 65 cm |
Number of stiff nodes (of edge elements) | 48 |
Loads from the bulk solid pressure were determined based on Eurocode 1, Part 4 [11], assuming the properties of wheat included in Table 4. Static calculations of the wheat silo were carried out for three sizes of eccentric of the discharge opening:
Physicomechanical properties of wheat adopted to determine the pressure in the silo chamber according to Eurocode 1, Part 4, Annex E [11].
Properties of bulk solid | Wheat | |||
---|---|---|---|---|
Average value | Parameter | Upper value | Lower value | |
Unit weight, γ [kN/m3] | - | - | 9.0 | 7.5 |
Internal friction angle, | 30 | 1.12 | 33.6 | 26.8 |
Concrete wall friction coefficient, μ | 0.57 | 1.16 | 0.661 | 0.491 |
(D3 wall type) | ||||
Lateral pressure ratio, | 0.54 | 1.11 | 0.599 | 0.486 |
Angle of repose, | 34 | |||
Patch load solid reference factor, | 0.5 | |||
a) Load combination I – symmetrical horizontal pressure and surface friction in connection with combination of randomly applied local loads on each silo ring respectively (Fig. 5a),
b) Load combination II – non-symmetrical pressure on the chamber perimeter, taking into account the flow channel for three values of the channel radius:
Based on the results obtained from numerical calculations using the finite element method for a reinforced concrete wheat silo with a height
Extreme values of internal forces in the wall of the silo with diameter
Values of internal forces | Level | |||
---|---|---|---|---|
0.25 | 0.75 | 0.5 | ||
-128.93 | -267.79 | -417.14 | ||
-137.93 | -276.44 | -426.79 | ||
-146.39 | -284.68 | -431.66 | ||
126.82 | 213.18 | 228.26 | ||
139.09 | 221.04 | 253.38 | ||
144.14 | 232.03 | 263.44 | ||
0.76 | 2.9 | 1.46 | ||
1.83 | 3.61 | 3.57 | ||
2.32 | 4.61 | 4.47 | ||
4.43 | 9.05 | 6.76 | ||
6.28 | 10.42 | 10.61 | ||
7.31 | 12.34 | 12.42 |
Extreme values of internal forces in the wall obtained taking into account the occurrence of an eccentric flow channel during silo emptying are presented in Table 6. In the case of eccentric emptying, the increase in the radius of the flow channel has a greater impact on the values of vertical forces (maximum differences are 35%) and a smaller effect on the values of hoop forces (the maximum differences are approximately 12%).
Extreme values of internal forces in the wall of the silo with the diameter
Values of internal forces | Level | |||
---|---|---|---|---|
0.25 | 0.5 | 0.75 | ||
–97.51 | –232.55 | –398.24 | ||
–112.27 | –254.48 | –433.87 | ||
–131.26 | –308.19 | –487.33 | ||
101.05 | 165.67 | 195.77 | ||
113.35 | 173.13 | 201.99 | ||
113.5 | 173.39 | 205.98 | ||
–1.09 | –2.31 | –2.89 | ||
–1.7 | –3.39 | –4.33 | ||
–2.39 | –4.65 | –5.58 | ||
–5.78 | –11.34 | –13.89 | ||
–8.54 | –16.34 | –19.91 | ||
–11.47 | –20.82 | –23.05 |
Percentage comparison of the calculated hoop moments taking into account the occurrence of the flow channel relative to the values calculated for the eccentricity limit
Percentage comparison of values of hoop moments in the silo with the diameter
Level, | Values of hoop moments, | ||||||
---|---|---|---|---|---|---|---|
% | % | % | |||||
0.25 | 4.43 | –5.78 | –8.54 | –11.47 | |||
0.5 | 9.05 | –11.34 | –16.34 | –20.82 | |||
0.75 | 6.76 | –13.89 | –19.91 | –23.05 |
Maps of vertical and hoop forces, as well as of hoop moments, in the silo for the case of occurrence of the flow channel specified with the middle angle θ
Figs. 7, 8 and 9 compare the distributions of hoop and vertical bending moments, as well as hoop forces, on the perimeter of the chamber in the mid-height region of the silo (
Compilation of the diagrams of hoop and vertical moments in the vertical cross-sections of the wall calculated taking into account the occurrence of the flow
channel have been shown in Fig. 10 (flow channel: cross-section A–A; channel edge: cross-section B–B).
In the case of combination of symmetrical pressure with local load, the researchers obtained higher values of hoop forces than when taking into account the occurrence of the flow channel (maximum differences are approximately 22%). On the other hand, creation of non-centric flow channel causes higher values of hoop and vertical moments in the silo wall than in the case of local loads.
Based on the multivariant numerical analysis of the complex (as well as static and dynamic random variables) load conditions of a cylindrical reinforced concrete wheat silo emptied on large eccentric (silo category AAC3), the authors formulated the following conclusions:
- Increasing the radius of the flow channel of the bulk solid in the silo causes local increases of both horizontal pressure and surface friction of the bulk solid in the flow zone.
- Redistribution of stresses in the silo wall under the influence of non-centric emptying, together with creation of the flow channel on a large eccentric, results in multiple increases of values of hoop and vertical moments in the silo wall in relation to emptying on a small eccentric.
- The eccentric of the flow channel during emptying of the silo on large eccentricities does not depend on the size of the eccentric of the discharge outlet (according to the procedure accepted in the Eurocode 1, Part 4).
- During side discharge of the bulk solid in the silo (eccentric of the discharge outlet equal to half of the diameter of the chamber), the method of determining non-symmetrical pressure raises doubts related to occurrence of underestimation of locally increased pressure of the bulk solid in the silo chamber.
Therefore, it is necessary to conduct experimental research on exploited silos and theoretical analyses on numerical models of silos emptied non-centrically on large eccentricities, in order to verify the methods of calculating non-symmetrical pressure of bulk solid and thereafter determine the complex stress states in the concrete structure of silos, which will affect their reliability.