The amount of particulate matter captured by the upstream and downstream segments of ventilated filters was directly determined by a UV method. With 25 mm 3.3 dpf/35000 total denier filters the dry particulate matter efficiency of the upstream section approximately doubled and the nicotine efficiency increased by about a half in going from 0 to 70 % tip ventilation. The efficiency of the downstream segment showed only minor variations. This resulted in an increase of total filtration efficiency from 48 % to 63 % for dry particulate matter and from 40 % to 49 % for nicotine. The dry particulate matter/nicotine ratio decreased from about 15 for non-ventilated cigarettes to less than 10 at 70 % tip ventilation because the tobacco column produced smoke containing relatively more nicotine and the difference between dry particulate matter and nicotine filtration efficiencies became successively larger as ventilation increased.