Open Access

A Study of Heat Generation in Orthopaedic Bone Drilling Process


Cite

1. Moldovan F, Bățagă T. Optimization of surgical bone drilling processes in repairing complete bone fractures. Acata Medica Marisiensis. 2019;65(1):30.Search in Google Scholar

2. Hosseini-Suny K, Momeni H, Janabi-Sharifi F. A Modified adaptive controller design for teleoperation systems. Robotics and Autonomous Systems. 2010;58:676–683.10.1016/j.robot.2009.11.006Search in Google Scholar

3. Unger B, Sepehri N, Rampersad V, Pisa J, Gousseau M, Hochman JB. Elements of virtual temporal bone surgery: Manipulandum format may be more important to surgeons than haptic device force capabilities. Laryngoscope Investig Otolaryngol. 2017;2(6):358–362.10.1002/lio2.120574316729299508Search in Google Scholar

4. Lévesque L, Noël JM, Scott C. Controlling the temperature of bones using pulsed CO2 lasers: observations and mathematical modeling. Biomed Opt Express. 2015;6(12):4768–4780.10.1364/BOE.6.004768467925226713192Search in Google Scholar

5. Feldmann A, Wandel J, Zysset P. Reducing temperature elevation of robotic bone drilling. Med Eng Phys. 2016;38(12):1495-150410.1016/j.medengphy.2016.10.00127789226Search in Google Scholar

6. Feldmann A, Maquer W, Zysset P. The thermal conductivity of cortical and cancellous bone. European Cells and Materials. 2018;35:25-33.10.22203/eCM.v035a0329376217Search in Google Scholar

7. Livingston A, Wang T, Christou C, Pelletier MH, Walsh WR. The Effect of saline coolant on temperature levels during decortication with a midas rex: an in vitro model using sheep cervical vertebrae. Front Surg. 2015;2:37.10.3389/fsurg.2015.00037452110026284253Search in Google Scholar

8. Tu YK, Chen LW, Ciou JS, Hsiao CK, Chen YC. Finite element simulations of bone temperature rise during bone drilling based on a bone analog. J Med Biol Eng. 2012;33(3):269-274.Search in Google Scholar

9. Ozdoganlar OB, DeVor RE, Kapoor SG. Modeling chip-evacuation forces and prediction of chip-clogging in drilling. J Manuf Sci Eng. 2002;124:605-614.10.1115/1.1473146Search in Google Scholar

10. Bertollo N, Walsh WR. Drilling of bone: practicality, limitations and complications associated with surgical drill-bits, in Vaclav Klika (eds): IntechOpen, London, UK, 2011, 53-82.10.5772/20931Search in Google Scholar

11. Lee JE, Rabin Y, Ozdoganlar OB. A new thermal model for bone drilling with applications to orthopaedic surgery. Med Eng Phys. 2011;33:1234–1244.10.1016/j.medengphy.2011.05.01421803638Search in Google Scholar

12. Zdero R, Tsuji MRS, Crookshank MC. Experimental methods in orthopaedic biomechanics, in Zdero R (eds): Academic Press, Elsevier, London, UK, 2017, 101-116.10.1016/B978-0-12-803802-4.00007-XSearch in Google Scholar

13. Hou Y, Li C, Ma H, Zhang Y, Yang M Zhang X. An Experimental research on bone drilling temperature in orthopaedic surgery. The Open Materials Science Journal. 2015;9:178-188.10.2174/1874088X01509010178Search in Google Scholar

14. Pandey RK, Panda SS. Drilling of bone: a comprehensive review. J Clin Orthop Trauma. 2013;4(1):15-30.10.1016/j.jcot.2013.01.002Search in Google Scholar

15. Boiadjiev G, Delchev K, Boiadjiev T, Zagurski T, Kastelov R, Vitkov V. Temperature reduction by controlled trust force during automatic bone drilling in the orthopedic surgery. 12th National Congress on Theoretical and Applied Mechanics, Varna Bulgaria, 2013, On-line available at: http://nctam.imbm.bas.bg/index.php/nctam/12nctam/paper/viewFile/514/14410.12732/ijpam.v88i4.12Search in Google Scholar

16. Alam K. Experimental measurements of temperatures in drilling cortical bone using thermocouples. Scientia Iranica B. 2015;22(2):487-492.Search in Google Scholar

17. Siljander BR, Wang AC, Zhang L, Shih AJ, Sullivan SE, Tai BL. Cool mist irrigation improves heat dissipation during surgical bone drilling. J Neurol Surg B Skull Base. 2014;75(4):243–246.10.1055/s-0034-1368098Search in Google Scholar

18. Augustin G, Davila S, Udilljak T, Staroveski T, Brezak D, Babic S. Temperature changes during cortical bone drilling with a newly designed step drill and an internally cooled drill. Int Orthop. 2012;36(7):1449–1456.10.1007/s00264-012-1491-zSearch in Google Scholar

19. Palmisano AC, Tai BL, Belmont B, Irwin TA, Shih A, Holmes JR. Heat accumulation during sequential cortical bone drilling. J Orthop Res. 2016;34:463-470.10.1002/jor.23044Search in Google Scholar

20. Hillery MT, Shuaib I. Temperature effects in the drilling of human and bovine bone. Journal of Materials Processing Technology. 1999;92-9:302-308.10.1016/S0924-0136(99)00155-7Search in Google Scholar

eISSN:
2247-6113
Language:
English
Publication timeframe:
6 times per year
Journal Subjects:
Medicine, Clinical Medicine, other