Open Access

Hydrogeophysical investigation of groundwater potential and aquifer vulnerability prediction in basement complex terrain – A case study from Akure, Southwestern Nigeria


Cite

[1] Wattanasen, K., Elming, S. (2008): Direct and indirect methods for groundwater investigations: A case study of MRS and VES in the Southern part of Sweden. Journal of Applied Geophysics, 66, pp. 104–117.10.1016/j.jappgeo.2008.04.005Search in Google Scholar

[2] Eze, C. L., Eze, E. M. (2015): Investigation of possible groundwater contamination from septic system siting in Port Harcourt, Nigeria. Journal of Natural Sciences Research, 5(10), pp. 83–87.Search in Google Scholar

[3] Asiwaju-Bello, Y. A., Olabode, F. O., Duvbiama, O. A., Iyamu, J. O, Adeyemo, A. A., Onigbinde, M. T. (2013): Hydrochemical evaluation of groundwater in Akure Area, Southwestern Nigeria, for irrigation purpose. European International Journal of Science and Technology, 2(8), pp. 235–249.Search in Google Scholar

[4] Hutchinson, P. J., Barta. L. S. (2002): VLF surveying to delineate longwall mine induced fractures. Leading Edge, pp. 491–493.10.1190/1.1481250Search in Google Scholar

[5] Olorunfemi, M. O., Fatoba, J. O., Ademilua, L. O. (2005): Integrated VLF-electromagnetic and electrical resistivity survey for groundwater in a crystalline basement complex terrain of Southwest Nigeria. Global Journal of Geological Sciences, 3(1), pp. 71–80.10.4314/gjgs.v3i1.18714Search in Google Scholar

[6] Bayewu, O. O., Oloruntola, M. O., Mosuro, G. O., Watabuni, F. G. (2012): Groundwater exploration in Ago-Iwoye Area of Southwestern Nigeria, using Very Low Frequency Electromagnetic (VLF-EM) and electrical resistivity methods. International Journal of Applied Sciences and Engineering Research, 1(3), pp. 452–462. doi: 10.6088/ijaser.002010104610.6088/ijaser.0020101046Search in Google Scholar

[7] Yadav, G. S., Singh, P. N., Srivastava, K. M. (1997): Fast method of resistivity sounding for shallow groundwater investigations. Journal of Applied Geophysics, 36, pp. 45–52.10.1016/S0926-9851(97)00009-8Search in Google Scholar

[8] Sundararajan, N., Nandakumar, G., Chary, M. N., Ramam, K. Srinivas, Y. (2007): VES and VLF—an application to groundwater exploration, Khammam, India. The Leading Edge, pp. 708–716.10.1190/1.2748489Search in Google Scholar

[9] Muchingami, I., Hlatywayo, D. J., Nel, J. M., Chuma, C. (2012): Electrical resistivity survey for groundwater investigations and shallow subsurface evaluation of the basaltic-greenstone formation of the urban Bulawayo aquifer. Physics and Chemistry of the Earth, 50–52, pp. 44–51.10.1016/j.pce.2012.08.014Search in Google Scholar

[10] Odusanya, B. O., Amadi, U. M. P. (1990): An empirical resistivity model for predicting shallow groundwater in the Basement Complex Water Resources. Journal of Nigeria Association of Hydrogeologists, 2, pp. 77–87.Search in Google Scholar

[11] Olayinka, A. I., Olorunfemi, M. O. (1992): Determination of geoelectrical characteristics in Okene area and implication for borehole siting. Journal of Mining and Geology, 28, pp. 403–412.Search in Google Scholar

[12] Olorunfemi, M. O., Fasuyi, S. A. (1993): Aquifer types and the geoelectric/hydrogeological characteristics of part of the central basement terrain of Nigeria (Niger State). Journal of African Earth Sciences, 16(3), pp. 309–316.10.1016/0899-5362(93)90051-QSearch in Google Scholar

[13] Dan-Hassan, M. A., Olorunfemi, M. O. (1999): Hydro-geophysical investigation of a basement terrain in the north central part of Kaduna State, Nigeria. Journal of Mining and Geology, 35(2), pp. 189–206.Search in Google Scholar

[14] Adepelumi, A. A., Akinmade, O. B., Fayemi. O. (2013): Evaluation of groundwater potential of Baikin Ondo State, Nigeria using resistivity and magnetic techniques: a case study. Universal Journal of Geoscience, 1(2), pp. 37–45.10.13189/ujg.2013.010201Search in Google Scholar

[15] Akinrinade, O. J., Olabode, O. P. (2015): Integrated geophysical approach to aquifer delineation in crystalline basement environment. International Journal of Scientific and Engineering Research (IJSER), France, 6(10), pp. 107–127.Search in Google Scholar

[16] Harb, N., Haddad, K., Farkh, S. (2010): Calculation of transverse resistance to correct aquifer resistivity of groundwater saturated zones: implications for estimating its hydrogeological properties, Lebanese Science Journal, 11(1), pp. 105–115.Search in Google Scholar

[17] Hutchinson, P. J., Beird, M. H., Mitchell, M. (2010): Groundwater purveying using very low frequency fracture delineation methods. Proceedings from the 2010 Symposium on the Application of Geophysics to Engineering and Environmental Problems, pp. 294–301. http://geo-image.com/documents/30.pdf10.4133/1.3445446Search in Google Scholar

[18] Hanchar, D. W. (1991): Effects of septic-tank effluent on groundwater quality in northern Willianson County and southern Davidson County, Tennessee. Water Resources Investigations Report 91–4011, US Geological Survey.Search in Google Scholar

[19] Panagiotakis, I., Dermatas, D., Vatseris, C., Chrysochoou, M., Papassiopi, N., Xenidis, A., Vaxevanidou, K. (2015): Forensic investigation of a Chromium VI groundwater plume in Thiva, Greece. Journal of Hazardous Materials, 281, pp. 27–34.10.1016/j.jhazmat.2014.09.04825450516Search in Google Scholar

[20] Banda, L. J., Mbewe, A. R., Nzala, S. H., Halwindi, H. (2014): Effect of siting boreholes and septic tanks on groundwater quality in St. Bonaventure Township of Lusaka District, Zambia. International Journal of Environmental Sciences Toxic Research, 2(9), pp. 191–198.Search in Google Scholar

[21] McQuillain, D. (2004): Ground-Water Quality Impacts From On-Site Septic Systems. Proceedings of 13th Annual Conference on National Onsite Wastewater Recycling Association, Albuquerque, New Mexico, pp. 1–13.Search in Google Scholar

[22] Henriet, J. P. (1976): Direct application of the Dar Zarrouk parameters in groundwater surveys. Geophysics Prospective, 24, pp. 344–353.10.1111/j.1365-2478.1976.tb00931.xSearch in Google Scholar

[23] Oladapo, M. I., Mohammed, M. Z., Adeoye, O. O., Adetola, B. A. (2004): Geoelectric investigation of the Ondo State Housing Corporation Estate, Ijapo Akure, southwestern Nigeria. Journal of Mining and Geology, 40(1), pp. 41–48.Search in Google Scholar

[24] Iloeje, N. P. (1981): A New Geography of Nigeria (New revised edition). Longman Nigeria Limited, Lagos, p. 201.Search in Google Scholar

[25] Rahaman, M. A. (1976): Review of the basement geology of southwestern Nigeria. In Geology of Nigeria, C. A. Kogbe (Ed.), Elizabethan Publishers, Lagos, pp. 41–58.Search in Google Scholar

[26] Omosuyi, G. O., Adegoke, A. O., Adelusi, A. O. (2008): Interpretation of Electromagnetic and Geoelectric Sounding Data for Groundwater Resources around Obanla-Obakekere, near Akure, Southwestern Nigeria. Pacific Journal of Science and Technology, 9(2), pp. 509–525.Search in Google Scholar

[27] Owoyemi, F. B. (1996): A Geological-Geophysical Investigation of Rain-Induced Erosional Features in Akure Metropolis. Unpublished M.Tech Thesis, Federal University of Technology Akure, Nigeria, pp. 11–18.Search in Google Scholar

[28] Karous, M., Hjelt, S. E. (1983): Linear filter of VLF dip-angle measurements. Geophysical Prospecting, 31, pp. 782–794.10.1111/j.1365-2478.1983.tb01085.xSearch in Google Scholar

[29] Poehls, D. J., Smith, G. J. (2009): Encyclopedic Dictionary of Hydrogeology. Elsevier Academic Research Incorporation, Amsterdam, ISBN 978-0-12-558690-0, p. 518.Search in Google Scholar