Open Access

The Efficiency of an Active Generator in the Case of a Deep Foundation Location

   | May 17, 2017

Cite

This paper presents a concept for vibration-mitigation techniques with the potential to reduce ground vibration amplitudes by applying an additional vibration source. The idea of an additional generator is verified in the case of an impact load for the points located on the ground surface and below it. Equations of motion for the damped transversally isotropic ground model with the absorbing boundary conditions are presented and numerically integrated using FlexPDE software, based on the finite element method. The efficiency of the solution is analyzed in terms of reducing the vertical and horizontal components. Results are presented in the form of a dimensionless amplitude reduction factor. In each case being analyzed, a vibration mitigation effect in a three-story building was achieved.

eISSN:
2083-831X
Language:
English
Publication timeframe:
4 times per year
Journal Subjects:
Geosciences, other, Materials Sciences, Composites, Porous Materials, Physics, Mechanics and Fluid Dynamics