Cite

Introduction. Chronic obstructive pulmonary disease (COPD) is associated with higher incidence of supraventricular arrhythmias. Atrial late potentials (ALP) detected by P-wave signal-averaged electrocardiography (SAECG) could be useful in detecting the patients at risk for supraventricular arrhythmias. Our objective was to assess the role of P-wave SAECG and ALP detection for arrhythmic risk evaluation of the patients with exacerbated COPD.

Methods. We prospectively included 45 patients with exacerbation of COPD and 58 age-matched patients with no history of pulmonary disease in a control group. We performed pulmonary function tests, arterial blood gases, echocardiography, 24-hour Holter monitoring and P-wave SAECG. We measured filtered P-wave duration (FPD), the root mean square (RMS) voltages in the last 40, 30 and 20 ms of the filtered P-wave (RMS 40, RMS 30 and RMS 20), the root mean square voltage of the filtered P-wave potentials (RMS-p), and the integral of the potentials during the filtered P-wave (Integral-p). ALP was defined as FPD > 132 ms and RMS 20 < 2.3 µV.

Results. Isolated atrial premature beats (APB) and supraventricular tachycardias (SVT) were more frequent in the COPD group. There were no significant differences between groups regarding the P wave SAECG parameters. In the COPD group none of the supraventricular arrhythmias was correlated with ALP or any P-wave SAECG parameters.

Conclusions. The patients with acute exacerbation of COPD but no apparent cardiac disease have a higher incidence of supraventricular arrhythmias. P-wave SAECG analysis and ALP detection have little value in the arrhythmic risk evaluation of these patients.

eISSN:
1220-4749
Language:
English
Publication timeframe:
4 times per year
Journal Subjects:
Medicine, Clinical Medicine, Internal Medicine, other, Cardiology, Gastroenterology, Rheumatology