The Laboratory of Natural Radiation (LNR) – a place to test radon instruments under variable conditions of radon concentration and climatic variables

Open access

Abstract

The publication of the new European Union Basic Safety Standards represents a remarkable milestone in the field of radiological protection in terms of adding radon exposure to this framework. Therefore, the coming years will bring the need to measure radon not only in the workplaces but also in the living spaces as a direct outcome of the application of the new EU Directive. So, the importance of having reliable instruments is evident and interlaboratory exercises are becoming more and more popular. However, most of them are carried out under constant conditions of meteorological variables. We present in this paper a facility to broaden the interlaboratory comparisons further by adding the study of radon exposures under real conditions of changes in climatic parameters. In addition, the facility has the possibility to verify the response of radon monitors when the radon concentration changes several orders of magnitude in a short period of time. Our work shows some results of one of the interlaboratory exercises carried out in the premises, where the radon levels were rather homogeneous in the testing room.

If the inline PDF is not rendering correctly, you can download the PDF file here.

  • 1.

    UNSCEAR. (2000). Sources and effects of ionizing radiation. Volume I: Sources; Volume II: Effects. (E.00.IX.3 and E.00.IX.4). New York: UN.

  • 2.

    Council of the European Union. (1996). Council Directive 96/29/EURATOM of 13 May 1996 laying down basic safety standards for the protection of the health of workers and the general public against the dangers arising from ionizing radiation. Brussels: O. J. EU.

  • 3.

    Council of the European Union. (2014). Council Directive 2013/59/EURATOM of 5 December 2013 laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation. Brussels: O. J. EU.

  • 4.

    EU. (1990). Directive 90/143/EURATOM of 21 February 1990 on the protection of the public against indoor exposure to radon. Commission recommendation. EU.

  • 5.

    Council of the European Union. (2013). Council Directive 2013/51/EURATOM of 22 October 2013 laying down requirements for the protection of the health of the general public with regard to radioactive substances in water intended for human consumption. Brussels: O. J. EU.

  • 6.

    International Standard Organization. (2010). Conformity assessment – general requirements for proficiency testing. ISO 17043.

  • 7.

    Gutierrez-Villanueva J. L. Sainz-Fernandez C. Fuente-Merino I. Saez-Vergara J. C. Correa-Garces E. & Quindos-Poncela L. S. (2014). The Spanish indoor radon mapping strategy. Radiat. Prot. Dosim.162(1/2) 58–62.

  • 8.

    SARAD GmbH. (2015). Radon Scout. Radon monitor for indoor measurements. Retrieved December 28 2015 from http://sarad.de/product-detail.php?p_ID=37.

  • 9.

    R Core Team. (2013). R: A language and environment for statistical computing. Vienna: R Foundation for Statistical Computing.

  • 10.

    Vander Heyden Y. & Smeyers-Verbeke J. (2007). Set-up and evaluation of interlaboratory studies. J. Chromatogr. A1158(1/2) 158–167.

  • 11.

    Wilrich P.-T. (2013). Critical values of Mandel’s h and k the Grubbs and the Cochran test statistic. AStA-Adv. Stat. Anal.97(1) 1–10.

  • 12.

    Wu G. B. & Meng H. (1996). Application and improvement of the Youden analysis in the intercomparison between flowmeter calibration facilities. Flow Meas. Instrum.7(1) 19–24.

Search
Journal information
Impact Factor

IMPACT FACTOR 2018: 0.585
5-year IMPACT FACTOR: 0.513

CiteScore 2018: 0.60

SCImago Journal Rank (SJR) 2018: 0.250
Source Normalized Impact per Paper (SNIP) 2018: 0.527

Metrics
All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 169 81 3
PDF Downloads 106 54 2