Numerical model of thyroid counter

Open access

Abstract

The aim of this study was to develop a numerical model of spectrometric thyroid counter, which is used for the measurements of internal contamination by in vivo method. The modeled detector is used for a routine internal exposure monitoring procedure in the Radiation Protection Measurements Laboratory of National Centre for Nuclear Research (NCBJ). This procedure may also be used for monitoring of occupationally exposed nuclear medicine personnel. The developed model was prepared using Monte Carlo code FLUKA 2011 ver. 2b.6 Apr-14 and FLAIR ver. 1.2-5 interface. It contains a scintillation NaI(Tl) detector, the collimator and the thyroid water phantom with a reference source of iodine 131I. The geometry of the model was designed and a gamma energy spectrum of iodine 131I deposited in the detector was calculated.

1. Koleska, M., Viererbl, L., & Marek, M. (2014). Development of the MCNPX model for the portable HPGe detector. Radiat. Phys. Chem., 104, 351–354.

2. Vrba, T., Nogueira, P., Broggio, D., Caldeira, M., Capello, K., Fantínová, K., Figueira, C., Hunt, J., Leone, D., Murugan, M., Marzocchi, O., Moraleda, M., Shutt, A., Suh, S., Takahashi, M., Tymińska, K., Lopez, M. A., & Tanner, R. (2014). EURADOS intercomparison exercise on MC modeling for the in-vivo monitoring of Am-241 in skull phantoms (Part I). Radiat. Phys. Chem., 104, 332–338.

3. Vrba, T., Broggio, D., Caldeira, M., Capello, K., Fantínová, K., Franck, D., Gómez-Ros, J. M., Hunt, J., Kinase, S., Leone, D., Lombardo, P. A., Manohari, M., Marzocchi, O., Moraleda, M., Nogueira, P., Ośko, J., Shutt, A., Suhl, S., Takahashi, M., Teles, P., Tremblay, M., Tymińska, K., Lopez, M. A., & Tanner, R. (2015). EURADOS intercomparison exercise on MC modeling for the in-vivo monitoring of Am-241 in skull phantoms (Part II and III). Radiat. Phys. Chem., 113, 59–71.

4. Battistoni, G., Cerutti, F., Fasso, A., Ferrari, A., Muraro, S., Ranft, J., Roesler, S., & Sala, P. R. (2007). The FLUKA code: Description and benchmarking. In M. Albrow, & R. Raja (Eds.), Proceedings of the Hadronic Shower Simulation Workshop 2006, Fermilab 68 September 2006. AIP Conference Proceeding, 896, 31–49.

5. Ferrari, A., Sala, P. R., Fasso, A., & Ranft, J. (2005). FLUKA: a multi-particle transport code. CERN-2005-10. INFN/TC_05/11, SLAC-R-773.

6. Guzik, Z., Borsuk, S., Traczyk, K., & Płominski, M. (2006). TUKAN: An 8K pulse height analyzer and multi-channel scaler with a PCI or a USB interface. IEEE Trans. Nucl. Sci., 53(1), 231–235.

7. Ośko, J., Golnik, N., & Pliszczyński, T. (2007). Spectrometric measurements of iodine and technetium activity in thyroid. Nucl. Instrum. Methods Phys. Res. Sect. A-Accel. Spectrom. Dect. Assoc. Equip., 580, 578–581.

8. Pliszczyński, T., Ośko, J., Filipiak, B., Golnik, N., & Haratym, Z. (2002). Measurement of activity of 131I deposited in human thyroid during the medical examination. Współczesna Onkologia, 6(8), 530–553. (in Polish).

Nukleonika

The Journal of Instytut Chemii i Techniki Jadrowej

Journal Information


IMPACT FACTOR 2017: 0.720
5-year IMPACT FACTOR: 0.610



CiteScore 2017: 0.64

SCImago Journal Rank (SJR) 2017: 0.294
Source Normalized Impact per Paper (SNIP) 2017: 0.509

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 68 68 3
PDF Downloads 16 16 0