Pulse Sequence Shaper For Radiospectroscopy And Relaxation Methods In NQR

Open access

Abstract

A pulse sequence shaper for the pursuance of the research using a wide spectrum of radiospectroscopy and relaxation methods in NQR is proposed. The distinctive feature of this product is its implementation with the application of a multi-functional programmable frequency synthesizer suitable for high-speed amplitude and phase manipulations.

[1] Ajoy, A., Alvarez, G.A., Suter, D. (2011). Optimal pulse spacing for dynamical decoupling in the presence of a purely dephasing spin bath. Physical Review A, 83(3), 032303/1–14.

[2] Itozaki, H., Ota, G. (2007). Nuclear quadrupole resonance for explosive detection. International Journal on Smart Sensing and Intelligent Systems, 1(3), 705–715.

[3] Kubasek, R., Alkhaddour, M. (2012). Building NMR/NQR Spectrometer. Proc. of Prog. in Electromagnetics Research Symposium, Moscow, Russia.

[4] Kay, L.E., Nicholson, L.K, Delaglio, F., Bax, A., Torchia, D.A. (1992). Pulse sequences for removal of the effects of cross correlation between dipolar and chemical-shift anisotropy relaxation mechanisms on the measurement of heteronuclear T1 and T2 values in proteins. Journal of Magnetic Resonance, 97(2), 359–375.

[5] Jie, S., Ying, L., Jianqi, L., Gengying, L. (2005). A powerful graphical pulse sequence programming tool for magnetic resonance imaging. Magnetic Resonance Materials in Physics, Biology and Medicine, 18(6), 332–342.

[7] Grzelak, S., Kowalski, M., Czoków, J., Zieliński, M. (2014). High resolution time-interval measurement systems applied to flow measurement. Metrol. Meas. Syst., 21(1), 77–84.

[8] Khandozhko, A.G., Khandozhko, V.A., Samila, A.P. (2013). A pulse coherent NQR spectrometer with effective transient suppression. Eastern-European Journal of Enterprise Technologies, 6/12(66), 21–25.

[10] Bopche, M.A., Deshmukh, A.Y. (2011). FPGA based direct digital synthesis function generator. International Journal of VLSI and Signal Processing Applications, 1(2), 8–14.

[11] Ridiko, L.I. DDS: Direct Digital Synthesizers. http://www.digit-el.com/files/articles/dds.pdf (Jul. 2014).

[12] Rudakov, T.N., Shpilevoi, A.A. (1997). An Input Device for the Receiving Channel of a Nuclear Quadrupole Resonance Spectrometer. Instruments and Experimental Techniques, 40(2), 215–216.

[13] Cyclone FPGA Family. Data Sheet for Altera, ver. 1.2. https://www.altera.com. (Jul. 2014).

Metrology and Measurement Systems

The Journal of Committee on Metrology and Scientific Instrumentation of Polish Academy of Sciences

Journal Information


IMPACT FACTOR 2016: 1.598

CiteScore 2016: 1.58

SCImago Journal Rank (SJR) 2016: 0.460
Source Normalized Impact per Paper (SNIP) 2016: 1.228

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 62 62 31
PDF Downloads 6 6 1