Method for Evaluating Discomfort Glare Based on the Analysis of a Digital Image of an Illuminated Interior

Open access

Abstract

The article proposes a method for measuring discomfort glare which uses numerical description of the phenomenon in the form of a digital luminance distribution map recorded on a CCD array. Essential procedures for determining partial quantities which are necessary for calculation of UGR index are discussed in detail, along with techniques for measuring position index and size of light sources, with regard to the parameters of the registering system and coordinates of the images of the sources on the array.

[1] Lindsay, P.H., Norman, D.A. (1977) Human information processing: An introduction to psychology. New York: Academic Press.

[2] International Lighting Vocabulary CIE17.4 (1987).

[3] EN 12665:2008, Light and lighting - Basic terms and criteria for determining the requirements forlighting (2008).

[4] EN 12464-1:2011 Light and lighting. Illumination of work places. Part 1: Indoor work places (2011).

[5] Technical Report: Discomfort Glare in Interior Lighting, CIE 117 (1995).

[6] CIE Collection on Glare CIE 146, 147:2002 (2002).

[7] Yamada, M., Fukuda, T. (1986) Quantitative evaluation of eye movements as judged by sight-line displacements, Journ. of Soc. of Mot. Pic. and Telev. Eng., (95), 1230−1241.

[8] Yamada, M., Fukuda, T., Hirota, M. (1990) Development of an eye-movement analyzer possessing functions for wireless transmission and autocalibration, Med. and Biol. Eng. and Conc., (28), 317−324.

[9] Schenkman, B., Fukuda, T., Persson, B. (1999) Glare from monitors measured with subjective scales and eye movements, Displays, (20), 11−21.

[10] Yamada, M., Fukuda, T., Hirota, M. (1989) A new eye movement analyzer: auto calibration and wireless transmission, In Proc. of IEEE Engineering in Medicine & Biology Society Conference, 861−863.

[11] Fugate J.M., Fry G.A. (1956) Relation of changes in pupil size to visual discomfort, Illum. Eng., (51), 537−549.

[12] Berman, S., Bullimore, M., Jacobs, R., Bailey, I., Gandhi, N. (1994) An objective measure of discomfort glare, Journ. of Illum. Eng. Soc., (23): 40−9.

[13] Belkic, K. (1986) Light stress and the cardiovascular system: the glare pressor test, Ergonomics, (29), 563−568.

[14] Murray, I.J., Plainis, S., Carden, D. (2002) The ocular stress monitor: a new device for measuring discomfort glare, Light. Res.&Techn., (34), 3: 231−242.

[15] Blaszczak, U.J. (2004) The method of estimation of background luminance in the objective glare measurements, Proceedings of SPIE, 5566, 234−238.

[16] Technical Report TC-3.4: Discomfort glare in the working environment, CIE, (1981).

[17] Wienold, J., Christoffersen, J. (2006) Evaluation methods and development of a new glare prediction model for daylight environments with the use of CCD camera, Energy and Buildings, (38), 743−757.

[18] Hirning, M.B. et al. (2013) Post occupancy evaluations relating to discomfort glare: A study of green buildings in Brisbane, Building and Environment, (59), 349−357.

Metrology and Measurement Systems

The Journal of Committee on Metrology and Scientific Instrumentation of Polish Academy of Sciences

Journal Information


IMPACT FACTOR 2016: 1.598

CiteScore 2016: 1.58

SCImago Journal Rank (SJR) 2016: 0.460
Source Normalized Impact per Paper (SNIP) 2016: 1.228

Cited By

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 131 131 8
PDF Downloads 74 74 7