The paper presents results of research aimed at determining the corrosive properties of steel with cathode metal coating in selected corrosive environments. The corrosion properties of the tin coated steel were evaluated using electrochemical impedance spectroscopy and potentiodynamic tests. For realised measurements, distilled water, 0.5 mol dm−3 NaCl solution, 0.1 mol dm−3 NaCl solution and SARS, which simulates acid rain were used as corrosive solutions. Both corrosion methods are suitable for diagnosing corrosion properties of steel with metal coatings.