Open Access

The influence of total reinforcement anchorage length on misinterpretation of the impact of hot-dip galvanised steel corrosion on its bond strength with concrete


Cite

To begin with, the intorduction of this paper summarises literature sources that wrongly interpret results of the bond strength between hot-dip galvanised reinforcements and concrete. The influence of the total reinforcement anchorage length on the bond strength results assessment was studied in detail. The numeric analysis of beam models with various testing anchorage lengths (the analysis input data comprised the results of previous bond strength tests carried out in a laboratory) unambiguously confirmed that when the bond strength between concrete and hot-dip galvanised reinforcement with a sufficient test anchorage length is tested in a beam test, the negative impact of the coating corrosion on bond strength with concrete may be biased. It is more objective to test bond strength with concrete in a pull-out test where a very short test reinforcement anchorage length is set out as a standard.

eISSN:
1804-1213
Language:
English
Publication timeframe:
4 times per year
Journal Subjects:
Industrial Chemistry, Chemical Engineering, Materials Sciences, Ceramics and Glass