Precise Compact System For Ionizing Radiation Detection And Signal Processing With Advanced Components Integration And Electronic Control

Open access

Abstract

Quality and performance of a detection system are the crucial parameters in all nuclear physics experiments. This system serves as a source of all signals and noises to be processed. Better performance, higher amplification and lower noises occurrence simplify subsequent signal analysis. In the field of Mössbauer spectroscopy, the spectrum quality and Mössbauer effect are crucial parameters which are affected especially by the quality of the detection system. These parameters were evaluated for different types of a detection setup. Finally an improvement of the spectrum quality by 15% and Mössbauer effect by 7% has been achieved for the natural iron reference absorber measurement in comparison with previous version of the detection system.

[1] YI, Q.—HONG, S.—JIE, K.—CHENG-FU, D.—XIAO-LI, M. —XIAO-GANG, L. : Development of Front-End Readout Electronics for Silicon Strip, Chinese Physics C 37 No. 1 (2013), 016101.

[2] ESPOSITO, B.—RIVA, M.—MAROCCO, D.—KASCHUCK, Y. : A Digital Acquisition and Elaboration System for Nuclear Fast Pulse Detection, Nuclear Instruments and Methods A No. 572 (2007), 355.

[3] ENGEL, G. L.—SADASIVAM, M.—NETHI, M.—ELSON, J. M.—SOBOTKA, L. G.—CHARITY, R. J. : A Multi-Channel Integrated Circuit for Use in Low-And Intermediate-Energy Nuclear Physics - HINP16C, Nuclear Instruments and Methods A No. 573 (2007), 418.

[4] PROCHAZKA, R.—MASLAN, M.—PECHOUSEK, J.—JANCIK, D. : Optimizing the Features of the Single-Channel Analyzer towards Improvement of Productivity of Mössbauer Spectra, Czechoslovak Journal of Physics No. 56 (2006), E133.

[5] PROCHAZKA, R.—PECHOUSEK, J.—FRYDRYCH, J. : Development of the Fast Scintillation Detector with Programmable High Voltage Adjustment Suitable for Möossbauer Spectroscopy, AIP Conference proceedings, 2010, p. 143.

[6] KWANG, H. K.—IN, S. J.—HO-SIK, Y. : Portable Gamma-Ray Tracking System for Nuclear Material Safety, Nuclear Instruments and Methods A No. 607 (2007), 64.

[7] Patent CN 102 798 881 (A), Nuclear radiation detection system, Ningbo Chi Ming Core Electronic Technology Co., Ltd.: Li Z., Application number CN 201210298203.

[8] Patent FR 2 973 116 (A1), Nuclear radiation detection device for use in key chain for detection of gamma and beta particles during disaster at nuclear power plant, Gregory J., Application number FR20110000853 20110322.

[9] Patent US 2 004 251 422 (A1), Ionization chamber detector system for the detection and measurement of nuclear radiation including beta, gamma, and x-ray radiation, Overhoff M., Application number US 10/766,717.

[10] Patent US 2 007 145 260 (A1), Instrumentation package and integrated radiation detector, General Electric Company: Frederick L., Medley D., Glesius F., Application numberUS 11/319,581.

[11] Patent WO 9 807 110 (A1), Ambient temperature cadmium zinc telluride radiation detector and amplifier circuit, Univ. California: Lavietes A. D., Mcquaid J. H., Application number PCT/US1997/013452.

[12] Patent US 4 336 532 (A), Integrated nuclear radiation detector and monitor, Radiation Engineering Inc.: Biehl B. L., Lieberman S. I., Application number US 06/152,273.

[13] MASHLAN, M.—JANCIK, D.—KHOLMETSKII, A.—MULABA, A.—POLLAK, H. : Mössbauer Spectrometer with YAlO3:Ce Scintillation Crystal, Hyperfine Interactions 120/121, 769.

[14] Patent CZ 302439 B6, Mössbauer Spectrometer, Palacky University Olomouc: Zboril R., Mashlan M., Kholmetskii A., Yevdokimov V., Application number CZ20050000422 20050629.

[15] Patent CZ 302515 B6, Mover for Mössbauer Spectrometer with Resonance Detection of Gamma Radiation, Palacky University Olomouc: Mashlan M., Pechousek J., Yevdokimov V., Application number CZ20040001064 20041022.

[16] Patent CZ 302779 B6, Mössbauer Spectrometer, Palacky University Olomouc: Prochazka R., Mashlan M., Tucek J., Tucek P., Pechousek J., Application number CZ20100000380 20100517.

[17] PECHOUSEK, J.—NOVAK, P.—NAVARIK, J.—KOHOUT, P.—MACHALA, L. : Mössbauer Spectroscopy System with Increased Performance and Flexibility – Utilization in Material Research, Journal of Electrical Engineering 64 No. 6 (2013), 386.

[18] PECHOUSEK, J.—PROCHAZKA, R.—PROCHAZKA, V.—FRYDRYCH, J. : Virtual Instrumentation Technique used in the Nuclear Digital Signal Processing System Design: Energy and Time Measurement Tests, Nuclear Instruments and Methods A No. 637 (2011), 200.

[19] NOVAK, P.—NAVARIK, J.—PECHOUSEK, J.—PROCHAZKA, V.—MACHALA, L.—TUCEK, J. : Development of Fast Pulse Processing Algorithm for Nuclear Detectors and its Utilization in LabVIEW-Based Mössbauer spectrometer, Journal of Instrumentation 9 (2014), article number T01001.

[20] Patent CZ 25467 U1, System for Detection of Ionizing Radiation, Palacky University Olomouc: Navarik J., Novak P., Pechousek J., Jancik D., Machala L., Mashlan M., Application number CZ20130028339U 20130820.

Journal of Electrical Engineering

The Journal of Slovak University of Technology

Journal Information


IMPACT FACTOR 2018: 0.636
5-year IMPACT FACTOR: 0.663

CiteScore 2018: 0.88

SCImago Journal Rank (SJR) 2018: 0.200
Source Normalized Impact per Paper (SNIP) 2018: 0.771

Cited By

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 124 67 6
PDF Downloads 126 106 18