Assessment of surgical sutures Polymed® by intracutaneous irritation test in rabbits

Open access

Abstract

The aim of the present study was to evaluate local irritant effects to rabbit skin following a single application of test samples of non-sterile polyamide non-absorbable surgical sutures POLYMED ®. The polar and nonpolar extracts were prepared by using saline solution and olive oil, respectively, after sinking the materials tested (2.0 g) in 10 ml of the corresponding liquid. Incubation was carried out at the temperature of 37°C for 72 h. The saline solution and pure olive oil, which had no contact with the materials tested, were used as negative control samples and were incubated under the same conditions as above. Assessments of the extracts from each material were conducted on 2 albino rabbits of the New Zealand breed. On the back of each animal, 5 intracutaneous injections of the extract tested and 5 injections of the control solution, each of 0.2 ml, were carried out. The degree of irritation was scored at 4, 24, 48, 72 hours after injection and no skin changes were found. The intracutaneous irritation index (III) was calculated and yielded 0.0. Hence it was concluded that under the experimental conditions the extracts of the material tested, i.e. non-sterile polyamide non-absorbable surgical sutures POLYMED ®, were ‘non-irritant’ to the skin of rabbits when compared with the respective control groups. The experimental procedure was conducted according to ISO10993-10.

If the inline PDF is not rendering correctly, you can download the PDF file here.

  • Buddy D et al. (2004). Lemons In vivo assessment of tissue compatibility in: Biomaterials Science: An Introduction to Materials in Medicine (James Anderson and Frederick Schoen eds) 362 Elsevier Academic Press 2nd ed.

  • Council of Europe. (1991). European Convention for the Protection of Vertebrate Animals used for Experimental and other Scientific Purposes. CETS No. 123.

  • ISO 10993-10: 2002(E). / Amd 1. 2006(E). (2006). Biological Evaluation of Medical Devices. Part 10: Tests for irritation and delayed hypersensitivity: Special irritation tests: Clause b.2: Intracutaneous (intradermal) reactivity tests.

  • ISO 10993-12: 2007(E). (2007). Biological Evaluation of Medical Devices. Part 12: Sample preparation and reference materials: Clause 10. Preparation of extracts of samples.

  • ISO 9001. (2008). Quality management systems.

  • Robinson V. (2005). Finding alternatives: an overview of the 3Rs and the use of animals in research. School Science Review 87(319): 111-114.

  • Saxena S et al. (2011). Development of a new polypropylene-based suture: plasma grafting surface treatment characterization and biocompatibility studies. Macromol Biosci 11(3): 373-82.

  • Upman PJ Anderson J Tasse L. (2003). An analysis of ISO intracutaneous reactivity test results to justify a reduction in animal requirements. Lab Anim32: 26-7.

  • USP 31. NF 26. (2008). Biological reactivity tests in vivo.