Open Access

Assessment of the Effect of the Pre-cast Beams IG Axial Spacing on the Effort Bridge Span


Cite

In designing of reinforced concrete bridges are often used pre-cast of pre-tensioned or post-tensioned prestressed members. In professional practice, when designing bridge span pre-cast of pre-tensioned prestressed beams IG type, different axial beams spacing’s are used and they are joined by a reinforced concrete slab. The paper presents a comparative analysis of an influence of the axial spacing of IG type beams in the cross-section of the bridge, on the bridge span effort, using standards PN-85/S-10042 and PN-EN 1992-2:2010. The optimal axial spacing of pre-cast IG type beams is presented, while maintaining the standard conditions of ULS (Ultimate Limit State). Such a solution has a positive impact on the costs of the entire project, significantly lowering the global investment cost.