Effect of scale deposits on the internal surfaces of the tubes on the superheater operation

Open access

Abstract

A mathematical model of the steam superheater exchanger with distributed parameters has been developed. Scale deposits were assumed to be present on the internal tube surfaces. It was assumed that the inner tube surfaces are covered by a thin layer of scale deposits. The finite volume method was used to solve partial differential equations describing flue gas, tube wall and steam temperature. The developed modeling technique can especially be used for modeling tube heat exchangers when detail information on the tube wall temperature distribution is needed. The numerical model of the superheater developed in the paper can be used for modeling of the superheaters with complex flow arrangement accounting scales on the internal tube surfaces. Using the model proposed the detailed steam, wall and flue gas temperature distribution over the entire superheater can be determined. The steam pressure distribution along its path flow and the total heat transfer rate can also be obtained. The calculations showed that the presence of scale on the internal surfaces of the tubes cause the steam temperature decrease and the heat flow rate transferred from the flue gas to the steam. Scale deposits on the inner surfaces of the tubes cause the tube wall temperature growth and can lead to premature wear of tubes due to overheating.

[1] Hewitt G.F., Shires G.L., Bott T.R.: Process Heat Transfer. CRC Press - Begell House, Boca Raton, 1994.

[2] Shah R.K., Sekulić D.P.: Fundamentals of heat exchanger design. Wiley, Hoboken, 2003.

[3] Kakaç S., Liu H.: Heat Exchangers: Selection, Rating, and Thermal Design, 2nd Edn. CRC Press-Taylor & Francis Group, Boca Raton, 2002.

[4] Lokshin V.A., Peterson D.F., Schwarz A.L.: Standard Methods of Hydraulic Design for Power Boilers. Hemisphere Publishing Corporation, Washington - New York - London, 1998.

[5] Kuznetsov N.W., Mitor W.W., Dubovski I.E., KarasinaE.S. (Eds.): Thermal Calculations of Steam Boilers (Standard Method), 2nd Edn. Energia, Moscow 1973, Russia.

[6] Lin Z.H.: Thermo-hydraulic design of fossil-fuel-fired boiler components. In: , Boilers, Evaporators, and Condensers (S. Kakac, Ed.), John Wiley & Sons Inc., Hoboken, 1991, 363-469.

[7] Taler J., Trojan M., Taler D.: Monitoring of Ash Fouling and Internal Scale Deposits in Pulverized Coal Fired Boilers. Nova Science Publishers Inc., New York2011.

[8] Taler D., Taler J.: Simplified analysis of radiation heat exchange in boiler superheaters.Heat Trans. Eng. 30(2009), 661-669.

[9] Ludowski P., Taler D., Taler J.: Identification of thermal boundary conditions in heat exchangers of fluidized bed boilers. Appl. Therm. Eng. 58(2013), 194-204.

[10] Rayaprolu K.: Boiler for Power and Process. CRC Press - Taylor & Francis Group, Boca - Raton 2009.

[11] French D.N.: Metallurgical failures in fossil fired boilers. 2nd Edn. John Wiley & Sons, New York 1993.

[12] Tzolakis G., Papanikolaou P., Kolokotronis D., Samaras N., Tourlidakis A., Tomboulides A.: Simulation of a coal-fired power plant using mathematical programming algorithms in order to optimize its efficiency. Appl. Therm.Eng. 48(2012) 256-267.

[13] Behbahaninia A., Bagheri M., Bahrampoury R.: Optimization of the fire tube heat recovery steam generators for cogeneration plants through genetic algorithm.Appl. Therm. Eng. 30(2010), 2378-2385.

[14] Xu L., Khan J.A., Chen Z.: Thermal load deviation model for superheater and reheater of a utility boiler. Appl. Therm. Eng. 20(2000), 545-558.

[15] Rahimi M., Khoshhal A., Shariati S.M.: CFD modeling of a boiler’s tubes rupture. Appl. Therm. Eng. 26(2006) 2192-2200.

[16] Purbolaksono J., Khinani A., Rashid A.Z., Ali A.A., Ahmad J., Nordin N.F.: A new method for estimating heat flux in superheater and reheater tubes. Nucl. Eng. Design 239(2009), 1879-1884.

[17] Othman H., Purbolaksono J., Ahmad B.: Failure investigation on deformed superheater tubes. Eng. Failure Anal. 16(2009), 329-339.

[18] Purbolaksono J., Ahmad J., Beng L.C., Rashid A.Z., Khinani A., Ali A.A.: Failure analysis on a primary superheater tube of a power plant. Eng. Failure Anal. 17(2010), 158-167.

[19] Pronobis M., Wojnar W.: The rate of corrosive wear in superheaters of boilers for supercritical parameters of steam. Eng. Failure Anal. 19(2012), 1-12.

[20] Harding N.S., O’Connor D.C.: Ash deposition impacts in the power industry. Fuel Proces. Techn. 88(2007), 1082-1093.

[21] Gnielinski V.: Heat transfer in cross-flow around single rows of tubes through tube bundles, 2nd Edn. In: VDI Heat Atlas, Springer, Berlin-Heidelberg 2010, G7, 725-730.

Archives of Thermodynamics

The Journal of Committee on Thermodynamics and Combustion of Polish Academy of Sciences

Journal Information


CiteScore 2016: 0.54

SCImago Journal Rank (SJR) 2016: 0.319
Source Normalized Impact per Paper (SNIP) 2016: 0.598

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 104 104 15
PDF Downloads 17 17 3