Search Results

1 - 6 of 6 items :

  • Spectroscopy and Metrology x
Clear All
Cutoff points of BMI for classification of nutritional status using bioelectrical impedance analysis

-Yap et al . (2000) Singapore 291 26.0 to 27.0 26.0 to 27.0 Frankenfield et al . (2001) US 141 22.6 20.1 Ko et al . (2001) China 5153 23.0 – 26.0 23.0 – 26.0 Dudeja et al . (2001) India 123 21.5 19.0 Oh et al . (2004) Korea 773915 25.0 25.0 Kagawa et al . (2006) Japan 139 - 23.0 Bozkirli et al . (2007) Turkey 909 28.24 28.02 Romero-Corral et al . (2008) US 13601 25.8 25.5 Laughton et al . (2009) Canada 77 22.1 22.1 Mialich et al . (2011

Open access
A new system for measuring electrical conductivity of water as a function of admittance

Wanga, and Zhiyu Wen, The Simulation of Frequency-Capacitance characteristics of Fresh Water Conductivity Sensor. Proceedings of the 2009 4th IEEE International Conference on Nano/Micro Engineered and Molecular Systems January 5-8, 2009, Shenzhen, China. Yia Jikun Lia Wei Wanga Lingfang Wen Zhiyu The Simulation of Frequency-Capacitance characteristics of Fresh Water Conductivity Sensor Proceedings of the 2009 4th IEEE International Conference on Nano/Micro Engineered and Molecular Systems January 5-8 2009 Shenzhen, China 6 Krishnan C.V., M

Open access
Design of current sources for load common mode optimization

with Optimized Output Impedance for Bioimpedance Measurements In Circuits and Systems (ISCAS) 2018 IEEE International Symposium on (pp 1 5 IEEE https://doi.org/10.1109/ISCAS.2018.835146 21 Li X, Dong F & Fu Y. (2012, May). Analysis of constant-current characteristics for current sources. In Control and Decision Conference (CCDC), 2012 24th Chinese (pp. 2607-2612). IEEE. https://doi.org/10.1109/CCDC.2012.624441 Li X Dong F Fu Y 2012 Analysis of constant-current characteristics for current sources In Control and Decision Conference

Open access
Development of a real-time, semi-capacitive impedance phlebography device

the second toe of the same leg. For this purpose, a commercially available finger clip device was used (CMS50E, Contec Medical Systems, Qinhuangdao, China). The recordings of the PPG signal were sampled with 60 Hz and the IPG signal with 64 Hz. For the evaluation two experimental setting as validation test were performed. The first evaluation step was the analysis of the influence of the capacitive measuring method on the signal quality and the detection of the pulse rate. For this, three different configurations were tested: a conductive coupling, a passive

Open access
Studies in Rheoencephalography (REG)

widely used in such nations as Austria, Italy, USA, Soviet Union/Russia, Poland, Belgium, Bulgaria, Hungary, China, and Spain. Following the development and computerization of neurological diagnostics and the wide use of a variety of brain mapping methods, interest in REG declined because of uncertainty about what aspects of brain circulation REG measures. An impedance brain scanner was mentioned in a 1978 publication [ 1 ], but no impedance scanner device was reported as being manufactured or applied to clinical practice. Currently no manufacturer has registered a REG

Open access