Search Results

You are looking at 1 - 4 of 4 items for

  • Author: Jarosław Karwacki x
Clear All Modify Search
Open access

Jarosław Karwacki, Helena Nowakowska, Marcin Lackowski and Dariusz Butrymowicz

Abstract

The paper presents numerical simulation of two-phase flow in a heated capillary with evaporation on the meniscus. To solve the problem, a model of evaporation from meniscus was developed in which the dynamics of liquid-vapour interface is described by the Cahn-Hilliard equation. The numerical simulations were performed using commercial software for 2D axially symmetric case. The flow evolution was analysed for different values of heat transfer coefficient at the capillary wall and inlet liquid mass flow rate.

Open access

Dariusz Butrymowicz, Jarosław Karwacki and Marian Trela

Abstract

Short state-of-the-art on the enhancement of condensation heat transfer techniques by means of condensate drainage is presented in this paper. The electrohydrodynamic (EHD) technique is suitable for dielectric media used in refrigeration, organic Rankine cycles and heat pump devices. The electric field is commonly generated in the case of horizontal tubes by means of a rod-type electrode or mesh electrodes. Authors proposed two geometries in the presented own experimental investigations. The first one was an electrode placed just beneath the tube bottom and the second one consisted of a horizontal finned tube with a double electrode placed beneath the tube. The experimental investigations of these two configurations for condensation of refrigerant R-123 have been accomplished. The obtained results confirmed that the application of the EHD technique for the investigated tube and electrode arrangement caused significant increase in heat transfer coefficient. The condensation enhancement depends both on the geometry of the electrode system and on the applied voltage.

Open access

Adam Dudar, Dariusz Butrymowicz, Kamil Śmierciew and Jarosław Karwacki

Abstract

Paper deals with theoretical analysis of possible efficiency increase of compression refrigeration cycles by means of application of a twophase ejector. Application of the two phase ejector in subcritical refrigeration system as a booster compressor is discussed in the paper. Results of exergy analysis of the system operating with various working fluids for various operating conditions have been shown. Analysis showed possible exergy efficiency increase of refrigeration compression cycle.

Open access

Dariusz Butrymowicz, Jarosław Karwacki, Roman Kwidziński, Kamil Śmierciew, Jerzy Gagan, Tomasz Przybyliński, Teodor Skiepko and Marek Łapin

Abstract

The theoretical basis for the indirect measurement approach of mean heat transfer coefficient for the packed bed based on the modified single blow technique was presented and discussed in the paper. The methodology of this measurement approach dedicated to the matrix of the rotating regenerative gas heater was discussed in detail. The testing stand consisted of a dedicated experimental tunnel with auxiliary equipment and a measurement system are presented. Selected experimental results are presented and discussed for selected types of matrices of regenerative air preheaters for the wide range of Reynolds number of gas. The agreement between the theoretically predicted and measured temperature profiles was demonstrated. The exemplary dimensionless relationships between Colburn heat transfer factor, Darcy flow resistance factor and Reynolds number were presented for the investigated matrices of the regenerative gas heater.