1 - 10 of 233 items :

  • Biomedical Electronics x
Clear All
An efficient and automatic ECG arrhythmia diagnosis system using DWT and HOS features and entropy- based feature selection procedure

Abstract

Primary recognition of heart diseases by exploiting computer aided diagnosis (CAD) machines, decreases the vast rate of fatality among cardiac patients. Recognition of heart abnormalities is a staggering task because the low changes in ECG signals may not be exactly specified with eyesight. In this paper, an efficient approach for ECG arrhythmia diagnosis is proposed based on a combination of discrete wavelet transform and higher order statistics feature extraction and entropy based feature selection methods. Using the neural network and support vector machine, five classes of heartbeat categories are classified. Applying the neural network and support vector machine method, our proposed system is able to classify the arrhythmia classes with high accuracy (99.83%) and (99.03%), respectively. The advantage of the presented procedure has been experimentally demonstrated compared to the other recently presented methods in terms of accuracy.

Open access
Knee-to-knee bioimpedance measurements to monitor changes in extracellular fluid in haemodynamic-unstable patients during dialysis

Abstract

The feasibility of bioimpedance spectroscopy (BIS) techniques for monitoring intradialytic changes in body fluids is advancing. The aim of this study was to compare the knee-to-knee (kkBIS) with the traditional whole-body (whBIS) with respect to continuous assessment of fluid volume status in hemodialysis patients. Twenty patients divided into two groups, hemodynamically stable and unstable, were recruited. Bioimpedance data from two different electrodes configurations (hand-to-foot and knee-to-knee) were collected and retrospectively analysed. A good correlation between the two methods with respect to changes in extracellular resistance (Re) and Re normalized for ultrafiltration volume (ΔRe/UFV) with p < 0.001 was observed. The relationship between relative change (%) in ΔRe and that in patient weight was most notable with kkBIS (4.82 ± 3.31 %/kg) in comparison to whBIS (3.69 ± 2.90 %/kg) in unstable patients. Furthermore, results based on kkBIS showed a reduced ability of the thigh compartments to keep up with the volume changes in the trunk for unstable patients. kkBIS provided a comparable sensitivity to whBIS even in patients at risk of intradialytic hypotension while avoiding the need for the complex implementation imposed by whBIS or other configurations.

Open access
Recognition of lung volume condition based on phase space mapping using electrical impedance tomography

Abstract

The purpose of this paper is to identify differences between abnormal and normal lung signals gathered by an EIT device, which is a new, non-invasive system that seeks the electrical conductivity and permittivity inside a body. Lung performances in patients are investigated using Phase Space Mapping technique on Electrical EIT signals. The database used in this paper contains 82 registered records of 52 individuals with proper lung volume. The results of this paper show that as the delay parameter (τ) increases, the SD1 parameter of phase space mapping indicates a significant difference between normal and abnormal lung volumes. The value of the SD1 parameter with τ = 6 in the case that the lung volume is in a normal condition is 342.57 ± 32.75 while it is 156.71 ± 26.01 in non-optimal mode. This method can be used to identify the patients’ lung volumes with chronic respiratory illnesses and is an accurate assessment of the diverse methods to treat respiratory system illnesses in addition to saving various therapeutic costs and dangerous consequences that are likely to occur by using improper treatment methods. It can also reduce the required treatment durations.

Open access
Segmental intracellular, interstitial, and intravascular volume changes during simulated hemorrhage and resuscitation: A case study

Abstract

This paper describes a new combined impedance plethysmographic (IPG) and electrical bioimpedance spectroscopic (BIS) instrument and software that will allow noninvasive real-time measurement of segmental blood flow, intracellular, interstitial, and intravascular volume changes during various fluid management procedures. The impedance device can be operated either as a fixed frequency IPG for the quantification of segmental blood flow and hemodynamics or as a multi-frequency BIS for the recording of intracellular and extracellular resistances at 40 discrete input frequencies. The extracellular volume is then deconvoluted to obtain its intravascular and interstitial component volumes as functions of elapsed time. The purpose of this paper is to describe this instrumentation and to demonstrate the information that can be obtained by using it to monitor segmental compartment volume responses of a pig model during simulated hemorrhage and resuscitation. Such information may prove valuable in the diagnosis and management of rapid changes in the body fluid balance and various clinical treatments.

Open access
Analysis of a Mechanistic Model for Non-invasive Bioimpedance of Intact Skin

Abstract

A mechanistic mathematical model for electrical impedance spectroscopy (EIS) measurements of human skin is analyzed, leading to a reduced model and approximate solutions. In essence, the model considers a complex-valued Laplace equation in the frequency domain for the alternating current from a circular EIS probe passing through the layers – stratum corneum, viable skin and adipose tissue – of human skin in the frequency range 1 kHz – 1 MHz. The reduced model, which only needs to be solved numerically for the viable skin with modified boundary conditions, is verified with the full set of equations (non-reduced model): good agreement is found with a maximum relative error of less than 3%. A Hankel transform of the reduced model allows for approximate solutions of not only the measured impedance but also the point-wise potential distribution in the skin. In addition, the dimensionless numbers governing the EIS are elucidated and discussed.

Open access
Application of genetic algorithm in extracting cell dielectric characteristics with electrorotation

Abstract

In this study the transformed theory is applied to derive the dielectric characteristics of cells, considering the electrorotation (ER) peak frequency. In current studies, estimations of low frequency, which are credible for the values less than 1 mS/m for medium conductivity, are used to obtain the corresponding permittivity and conductivity of cells. Unlike the presented works, the transformed theory applies the comprehensive statement for corresponding permittivity and conductivity of cells. In the transformed theory, the membrane and interior characteristics could be obtained from the high and the low frequencies of peak ER, for all values of conductivity of medium. Characteristics of cells are obtained via optimization of an equation for the conductivity of medium regarding the peak ER frequency. The optimization process is performed applying genetic algorithm due to its swift adaptation to the problem and faster convergence.

Open access
Bioelectrical impedance analysis of body composition: influence of a newly implanted cardiac device

Abstract

Current guidelines do not recommend bioelectrical impedance analysis (BIA) in patients with implanted cardiac devices. There is no data on the influence of such devices over the parameters assessed by BIA. We aimed to assess the influence of cardiac devices on the parameters assessed by BIA as well as to evaluate the likelihood of electromagnetic interference of BIA in patients with implanted cardiac devices. Sixty-two consecutive patients over 18 years of age who underwent single (PM) or multisite (CRT) pacemaker or defibrillator (ICD) implantation were included. Body composition assessment was done using a single frequency device, on both right and left sides, before and after cardiac device implantation. During BIA analysis after device implantation, we did real-time telemetry to assess electromagnetic interference. Patients were 67+14 years old and 51.6% male. PM was implanted in 52 patients (83.9%), ICD in 7 (11.3%), ICD with CRT in 2 (3.2%) and CRT in 1 (1.6%). During real-time telemetry, there was no electromagnetic interference including interruption of telemetry. Default device programming did not change after BIA assessment. After surgery, resistance and fat mass were smaller, while cellular mass, fat-free mass, metabolic rate and total body water/ body weight increased, on right and left sides measurements. We concluded that decreased resistance and related parameters after device implantation were probably influenced to a change in hydration status, regardless of the implanted device. Bioimpedance analysis is safe in patients with an implanted cardiac device.

Open access
Biomass measurement of living Lumbriculus variegatus with impedance spectroscopy

Abstract

Impedance spectroscopy is a useful tool for non-invasive and real time measurements of cell suspensions and a variety of biological tissues. The objective of this study was the investigation of the dielectric properties of living aquatic worms (Lumbriculus variegatus) using impedance spectroscopy in a frequency range between 100 Hz and 10 MHz. We demonstrate a linear relation between the worm biomass and the phase response of the signal thereby providing a quick and precise method to determine the biomass of aquatic worms in situ. Possible applications for non-destructive online biomass monitoring of aquatic worms and other aqueous organisms are discussed. Furthermore, we show that groups of worms fed different diets can be distinguished by the method presented. These results reveal a close relationship between the nutritional composition of the worms and the measured phase response. We also demonstrate that the phase response at 90 kHz does not depend on the worm size. In contrast, the response function for the signal at 440 Hz reveals a linear correlation of average individual worm size and phase. Therefore, we conclude that the measured phase response at 90 kHz qualifies as a measure of the total amount of worm biomass present in the measuring cell, whereas the phase measurement at 440 Hz can be used to estimate the average individual worm size.

Open access
Body composition assessment by bioelectrical impedance analysis and body mass index in individuals with chronic spinal cord injury

Abstract

Purpose: To assess body composition and obesity in individuals with spinal cord injury (SCI) who practice and do not practice physical activity using body mass index (BMI) and bioelectrical impedance analysis (BIA). Methods: 39 patients with SCI went through BIA evaluation and BMI was assessed. Patients were divided into four groups according to injury level (paraplegia or tetraplegia) and physical activity achievement (active or inactive). Results: 22 individuals with paraplegia (7 active and 15 inactive) and 17 with tetraplegia (5 active and 12 inactive) were evaluated. BMI, fat percentage, fat mass, lean tissue mass, total body water (TBW), and TBW percentage were assessed in groups. Tetraplegic inactive groups showed higher fat percentage featuring obesity. For paraplegic active group mean fat percentage was 19.61% (±9.27) and mean fat mass was 16.66 kg (±9.71) and for paraplegic inactive group fat percentage was 23.27% (±5.94) and fat mass 18.59 kg (±7.58). For tetraplegic groups in active group the fat percentage was 17.14% (±6.32) and fat mass was 11.22 kg (±5.16) and for inactive group mean fat percentage was 33.68% (±4.74) and fat mass was 25.59 kg (±2.91). When paraplegic and tetraplegic inactive groups were compared differences were observed in fat percentage (p = 0.0003) and fat mass (p = 0.0084). Also, when tetraplegic groups (activeXinactive) were compared differences in percentage (p = 0.0019) and fat mass (p = 0.034) were observed. Only for the paraplegic inactive group BMI result was higher than 25 kg/m2. Conclusion: BMI does not discriminate between obesity levels in individuals with SCI and physical activity can improve body composition and prevent obesity in SCI patients.

Open access
Bones, blood and steel: How bioelectrical impedance analysis is affected by hip fracture and surgical implants

Abstract

Introduction

Bioelectrical impedance analysis (BIA) is in widespread use, but there is uncertainty about its validity in patients with metal implants or after acute hip fracture and surgery. We aimed to investigate the use of single frequency tetrapolar BIA in patients with hip fracture by answering the following questions: 1) Are BIA measurements affected by recent hip fracture and surgical repair? 2) Are BIA measurements affected by the presence of metal implants used in hip fracture surgery?

Setting

Two hospitals in Bergen, Norway.

Participants

A convenience sample of 203 acute hip fracture patients.

Methods

Participants had their body composition measured by single frequency, tetrapolar BIA on the fractured and unfractured side of the body in the immediate postoperative period and at follow-up three months after hip fracture. Measurements from fractured and unfractured side and measurements in hospital and at follow-up were compared. BIA readings for hips treated with cannulated screws, compression hip screw and hip arthroplasty were compared.

Results

Resistance was lower on the side of the fractured hip compared to the unfractured side postoperatively, but not at follow-up. BIA readings did not differ by type of surgical implant.

Conclusion

Recent fracture and surgery influences single frequency tetrapolar BIA resistance. The presence of surgical implants in the hip do not affect BIA measurements. If BIA is used in acute hip fracture patients, the contralateral side to the fracture should be measured.

Open access