Relining of pipe systems: conditions, benefits and application through case-study

Open access

Abstract

Relining is one of the best alternatives available today for pipe system rehabilitation. This trenchless solution is particularly interesting for urban agglomerations, as a smaller diameter pipe is pushed or pulled through the old pipeline. Relining creates a leak-tight “pipe within a pipe” system, which is as good as new in both structural and hydraulic terms. Relining can be performed with both circular and special, non-circular (NC) profiles. The latter is especially advantageous for the rehabilitation of old sewers, many of which were constructed in a variety of ovoid-like shapes. This paper presents the typical steps that are performed for pipeline rehabilitation with non-circular profiles, as well as an applied case study (a project implemented in the city of Würzburg in Germany).

If the inline PDF is not rendering correctly, you can download the PDF file here.

  • [1] Bianchi S. Final Report Summary Novel Technology for Low Cost Re-lining of Pipe Infrastructure Italian Association for Trenchless Technology (IATT) CORDIS European Commission's Portal pp.1 2014

  • [2] CEN European Committee for Standardization EN 752 Drain and sewer systems outside buildings (Part V: Rehabilitation) 1997

  • [3] CEN European Committee for Standardization EN 1610 Construction and testing of drains and sewers 2011

  • [4] DWA (German Association for Water Wastewater and Waste) ATW DVWK M 127 Static calculations for the rehabilitation of sewers and drains with lining and assembly process (Part 2) 2010

  • [5] Matthews J.C. How to select the proper relining method for your work Trenchless Technology - Pipe Relining Supplement pp.14 2013

  • [6] McKim R.A. Bidding Strategies for Trenchless Technologies Cost Engineering Vol. 40 pp. 37-41 1998.

  • [7] Morrison R. et.al State of Technology for Rehabilitation of Water Distribution Systems Environmental Protection Agency (EPA) pp.3 2013

  • [8] Municipality report Kanalbaumanagementbericht Municipality of Würzburg pp. 33-35 pp. 42-48 2014

  • [9] Najafi M. Trenchless Technology: Planning Equipment and Methods New York: McGraw-Hill Companies Inc. 2013

  • [10]. Najafi M S. Salem D. Bhattachar B. Salman and R. Patil An Asset Management Approach for Drainage Infrastructure and Culvert Midwest Regional University Transportation Center College of Engineering University of Wisconsin Madison 2008

  • [11] Product catalogue NC Line. Non-Circular Profiles HOBAS Pipes International GmbH 2014

  • [12] Zhao J. Q. Slipline Rehabilitation of Watermains with High-Density Polyethylene Pipe Construction Technology Updates Number 56 Institute for Research in Construction National Research Council of Canada pp.1-3 2013

  • [13] Zhao J.Q. and Daigle L. Structural Performance of Sliplined Watermain Canadian Journal of Civil Engineering Vol. 28 No. 6 pp. 969-978 2001.