Relining of pipe systems: conditions, benefits and application through case-study

Open access

Abstract

Relining is one of the best alternatives available today for pipe system rehabilitation. This trenchless solution is particularly interesting for urban agglomerations, as a smaller diameter pipe is pushed or pulled through the old pipeline. Relining creates a leak-tight “pipe within a pipe” system, which is as good as new in both structural and hydraulic terms. Relining can be performed with both circular and special, non-circular (NC) profiles. The latter is especially advantageous for the rehabilitation of old sewers, many of which were constructed in a variety of ovoid-like shapes. This paper presents the typical steps that are performed for pipeline rehabilitation with non-circular profiles, as well as an applied case study (a project implemented in the city of Würzburg in Germany).

[1] Bianchi S., Final Report Summary Novel Technology for Low Cost Re-lining of Pipe Infrastructure, Italian Association for Trenchless Technology (IATT), CORDIS European Commission's Portal, pp.1, 2014

[2] CEN European Committee for Standardization, EN 752 Drain and sewer systems outside buildings (Part V: Rehabilitation), 1997

[3] CEN European Committee for Standardization, EN 1610 Construction and testing of drains and sewers, 2011

[4] DWA (German Association for Water, Wastewater and Waste), ATW DVWK M 127 Static calculations for the rehabilitation of sewers and drains with lining and assembly process (Part 2), 2010

[5] Matthews J.C., How to select the proper relining method for your work, Trenchless Technology - Pipe Relining Supplement, pp.14, 2013

[6] McKim R.A., Bidding Strategies for Trenchless Technologies, Cost Engineering, Vol. 40, pp. 37-41, 1998.

[7] Morrison R. et.al, State of Technology for Rehabilitation of Water Distribution Systems, Environmental Protection Agency (EPA), pp.3, 2013

[8] Municipality report, Kanalbaumanagementbericht, Municipality of Würzburg, pp. 33-35, pp. 42-48, 2014

[9] Najafi M., Trenchless Technology: Planning, Equipment, and Methods, New York: McGraw-Hill Companies, Inc., 2013

[10]. Najafi M, S. Salem, D. Bhattachar, B. Salman, and R. Patil, An Asset Management Approach for Drainage Infrastructure and Culvert, Midwest Regional University Transportation Center, College of Engineering, University of Wisconsin, Madison, 2008

[11] Product catalogue, NC Line. Non-Circular Profiles, HOBAS Pipes International GmbH, 2014

[12] Zhao J. Q., Slipline Rehabilitation of Watermains with High-Density Polyethylene Pipe, Construction Technology Updates Number 56, Institute for Research in Construction, National Research Council of Canada, pp.1-3, 2013

[13] Zhao J.Q. and Daigle L., Structural Performance of Sliplined Watermain, Canadian Journal of Civil Engineering, Vol. 28, No. 6, pp. 969-978, 2001.

Journal Information

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 531 531 5
PDF Downloads 92 92 5