Cabling Arrangement Influence on Repeatability of Immunity EMC Measurements

Open access

Cabling Arrangement Influence on Repeatability of Immunity EMC Measurements

The paper deals with the analysis of induced current of differential loops of transmission lines during immunity test against electromagnetic field measurement. The influence of geometrical configuration of cabling arrangement on induced current values is surveyed. The problem is described for the case of a short two-wire line creating differential mode loop. The current induced at both ends of the line is the characteristics observed in the performed studies. The comparison between the results of measurements on real physical line, numerical simulations and analytical solution is presented.

Paul, C. R. (1994). Analysis of multiconductor transmission lines. New York, USA: Wiley Interscience.

Paul, C. R. (1994). A SPICE model for multiconductor transmission lines excited by an incident electromagnetic field. IEEE Transactions on Electromagnetic Compatibility36(4), 342 - 354.

Beggio, A., Bono, G., Zich, R. E. (1999). Analysis of the unwanted effects on the radiated emissions and susceptibility measurements due to the introduction of a wooden table. In IEEE EMC Symposium 1999, 2-6 August 1999 (pp. 761-764). Seattle, USA.

Beeckman, P. A. (2001). The influence of positioning tables on the results of radiated EMC measurements. In IEEE EMC Symposium 2001, 13-17 August 2001 (pp. 280-285). Montreal, Canada.

Omid, M., Kami, Y., Hayakawa, M. (1997). Field coupling to nonuniform and uniform transmission lines. IEEE Transactions on Electromagnetic Compatibility39(3), 201 - 211.

Adams, J. W., Cruz, J., Melquist, D. (1992). Comparison measurements of currents induced by radiation and injection. IEEE Transactions on Electromagnetic Compatibility34(3), 360-362.

ANALOG DEVICES, Inc. (2003) Low cost DC-500 MHz, 92 dB logarithmic amplifier AD8307. Retrieved November 2003, from http://www.analog.com

Electromagnetic compatibility (EMC) - part 4-3: testing and measurement techniques - radiated, radio-frequency, electromagnetic field immunity test. (1996). Slovak version of European standard. STN EN 61000-4-3.

Measurement Science Review

The Journal of Institute of Measurement Science of Slovak Academy of Sciences

Journal Information


IMPACT FACTOR 2017: 1.345
5-year IMPACT FACTOR: 1.253



CiteScore 2017: 1.61

SCImago Journal Rank (SJR) 2017: 0.441
Source Normalized Impact per Paper (SNIP) 2017: 0.936

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 96 96 10
PDF Downloads 24 24 1