Haemodynamics imaging of swine segmental kidney artery using duplex Doppler technique

Open access

Abstract

Introduction: The aim of the study was to assess the usefulness of duplex Doppler to objectify swine renal arterial flow in physiological conditions. The pig kidney was selected for its morphological similarities to the human and for the results therefore offering data to wider research. Material and Methods: Six White Large x Landrace sows, of 48.5–53 kg b.w. were used. Vascular flow parameters were acquired with a convex probe USG device with a duplex Doppler function using pulsed waves (frequency range of 5–7.5 MHz). Segmental kidney arterial flow was measured. Results: The RI values were within the 0.57 (min) to 0.6 (max) range, ̄xRI was 0.58 (±0.014), and the SD2 value was 0.0002. The PI index values ranged from 1.21 (min) to 1.3 (max), and ̄xRI was 1.24 (±0.035). The value of SD2 was 0.00123. In the S/D index, the results fell between 2.2 (min) and 2.49 (max), with ̄xS/D of 2.29 (±0.117). The value of variance SD2 was 0.0139. A double analysis of correlation between indices showed this to be almost certain and highly positive as confirmed by high correlation coefficients: r RI & PI 0.857, rho RI & PI 0.739, r RI & S/D 0.930, rho RI & S/D 0.941, r PI & S/D 0.913, and rho PI & S/D 0.754. The segmental kidney arterial flow spectrum evinced falls in PSV and PSV/LDV ratio, also noticed in the filling of the spectral window, comparing the renal to an interlobar artery. Conclusion: Swine were selected because of renal anatomical and haemodynamic similarity to humans. The most relevant values and indices approximated those in humans. The study anaesthetic protocol had a minor influence on the average RI, PI, and S/D indices.

1. Atalabi O.M., Afolabi O.S., Asinobi A.O.: Renal Doppler indices in children with nephrotic syndrome: findings from a tertiary hospital in Nigeria. Niger. J Physiol Sci 2015, 30, 17–23.

2. Bude R.O., DiPietro M.A., Platt J.F., Rubin J.M., Miesowicz S., Lundquist C.: Age dependency of the renal resistive index in healthy children. Radiology 1992, 184, 469–473.

3. Carvalho C.F., Chammas M.C.: Normal Doppler velocimetry of renal vasculature in Persian cats. J Feline Med Surg 2011, 13, 399–404.

4. Chu Y., Liu H., Xing P., Lou G., Wu C.: The morphology and haemodynamics of the rabbit renal artery: evaluation by conventional and contrast-enhanced ultrasonography. Lab Anim 2011, 45, 204–208.

5. Commission of the European Communities. Third report from the Commission to the Council and the European Parliament on the statistics on the number of animals used for experimental and other scientific purposes in the member states of the European Union. Brussels, 2002.

6. Gaviria E.J., Restrepo J.G., Marín J.D., Arango G., Aramburo D., Franco F., Tintinago L.F.: Evaluation of propofol as an anesthetic in swine tracheal transplant surgery. Rev Col Cienc Pec 2007, 20, 447–454.

7. Gudmundsson S., Maršál K.: Doppler ultrasound examination of the renal artery in healthy women, normotensive pregnant women, and in pre-eclampsia. Ultrasound Obstet Gynecol 1991, 1, 258–260.

8. Henes F.O., Regier M., Bannas P., Henker M., Heinemann A., Sperhake J., Begemann P.G., Adam G., Groth M.: Early time-related course of image findings in postmortem MRI: typical findings and observer agreement in a porcine model. Leg Med 2017, 28, 15-21.

9. In-Chul P., Hye-Sun L., Jong-Taek K., So-Jeong N., Ran Ch., Ki-Seok O., Chang-Ho S., Changbaig H.: Ultrasonographic evaluation of renal dimension and resistive index in clinically healthy Korean domestic short-hair cats. J Vet Sci 2008, 9, 415–419.

10. Kaya M., Pekcan Z., Sen Y., Boztok B., Senel O.O., Bumin A.: Effects of short-acting anaesthetics on haemodynamic function as determined by Doppler US in rabbits. Kafkas Univ Vet Fak Derg 2011, 17, 713–719.

11. Keogan M., Kliewer M., Hertzberg B., DeLong D.M., Tupler R.H., Carroll B.A.: Renal resistive indexes: variability in Doppler US measurement in a healthy population. Radiology 1996, 199, 165–169.

12. Kim S.H.: The usefulness of pulsatile flow detection in measuring resistive index in renal Doppler US. Korean J Radiol 2002, 3, 45–48.

13. Kujawa-Szewieczek A., Kolonko A., Chudek J., Więcek A.: No effect of pretransplantation bilateral nephrectomy on the resistive indices measured in the kidney allograft. Transplant Proc 2014, 46, 2602–2605.

14. Lin G.J., Cher T.W.: Renal vascular resistance in normal children - a color Doppler study. Pediatric Nephrol 1997, 11, 182–185.

15. Lind N.M., Moustgaard A., Jelsing J., Vajta G., Cumming P., Hansen A.K.: The use of pigs in neuroscience – modeling brain disorders. Neurosci Biobehav Rev 2007, 31, 728–743.

16. Mitchell S.K., Toal R.L., Daniel G.B., Rohrbach B.W.: Evaluation of renal hemodynamics in awake and isofluoraneanesthetized cats with pulsed-wave Doppler and quantitative renal scintigraphy. Vet Radiol Ultrasound 1998, 39, 451–458.

17. Möckel M., Scheinert D., Potapov E.V., Wellnhofer E., Combé V., Nasseri B.A., Maier D., Meyer S., Yankah C., Hetzer R., Frei U., Eckardt K.U.: Continuous measurements of renal perfusion in pigs by means of intravascular Doppler. Kidney Int 2001, 59, 1439–1447.

18. Naqvi J., Yap K.H., Ahmad G., Ghosh J.: Transcranial Doppler ultrasound: a review of the physical principles and major applications in critical care. Int J Vasc Med 2013, 6, 1–13.

19. Ozel D., Ozel B.D., Ozkan F., Kutlu R.: Evalution of renal involvement in patients with Behçet disease: Need to be aware about potential hypertension in long term follow up? Pol J Radiol 2016, 81, 5–9.

20. Pope J.C., Hernanz-Schulman M., Showalter P.R., Cole T.C., Schrum F.F., Szurkus D., Brock J.W.: The value of Doppler resistive index and peak systolic velocity in the evaluation of porcine renal obstruction. J Urol 1996, 156, 730–733.

21. Rawashdeh Y.F., Mortensen J., Horlyck A., Olsen K.O., Fisker R.V., Schroll L., Frokiaer J.: Resistive index: an experimental study of normal range in the pig. Scand J Urol Nephrol 2000, 34, 10–14.

22. Rivers B.J., Walter P.A., Letourneau J.G., Finlay D.E., Ritenour E.R., King V.L., O’Brien T.D., Polzin D.J.: Duplex Doppler estimation of resistive index in arcuate arteries of sedated, normal female dogs: implications for use in the diagnosis of renal failure. J Am Anim Hosp Assoc 1997, 33, 69–76.

23. Rivers B.J., Walter P.A., O’Brien T.D.: Duplex Doppler estimation of Pourcelot resistive index in arcuate arteries of sedated normal cats. J Vet Intern Med 1996, 10, 28–33.

24. Rivers B.J., Walter P.A., Polzin D.J., King V.L.: Duplex doppler estimation of intrarenal pourcelot resistive index in dogs and cats with renal disease. J Vet Intern Med 1997, 11, 250–260.

25. Rodrigues A.C., Santos L.C.D., Otsuki D.A., Saad K.R., Saad P.F., Montero E.F.S., Utiyama E.M.: Animal model of continuous peritoneal lavage with vacuum peritoneostomy. Acta Cir Bras 2017, 32, 467–474.

26. Sauerbrey A., Hindel S., Maaß M., Krüger Ch., Wissmann A., Kramer M., Nafz B., Lüdemann L.: Establishment of a swine model for validation of perfusion measurement by dynamic contrast-enhanced magnetic resonance imaging. BioMed Res Int 2014, 7, 1–9.

27. Shoemarker W.: Relation of oxygen transport patterns to the pathophysiology and therapy of shock states. Intensive Care Med 1987, 13, 230–243.

28. Shokeir A.A., Abdulmaaboud M.: Prospective comparison of non-enhanced helical computerized tomography and Doppler US for the diagnosis of renal colic. J Urol 2001, 165, 1082–1084.

29. Stygar A.H., Dolecheck K.A., Kristensen A.R.: Analyses of body weight patterns in growing pigs: a new view on body weight in pigs for frequent monitoring. Animal 2018, 12, 295–302.

30. Sullivan T.P., Eaglstein W.H., Davis S.C., Mertz P.: The pig as a model for human wound healing. Wound Repair Regener 2001, 9, 66–76.

31. Swindle M.M., Makin A., Herron A.J., Clubb F.J., Frazier K.S.: Swine as models in biomedical research and toxicology testing. Vet Pathol 2012, 49, 344–356.

32. Takano R., Ando Y., Taniguchi N., Itoh K., Asano Y.: Power Doppler sonography of the kidney: effect of Valsalva’s maneuver. J Clin Ultrasound. 2001, 29, 384–388.

33. Trafidło T., Gaszyński W., Gaszyński T.: The contemporary conversion of the haemodynamic monitoring paradigms in a shock. Anestezjol Ratownictwo 2010, 4, 99–110.

34. Tublin M.E., Bude R.O., Platt J.F.: The resistive index in renal Doppler sonography: where do we stand? Am J Roentgenol 2003, 180, 885–892.

35. Zhang H., Xing X., Wang Z., He M.: Evaluation of split renal function for children with kidney diseases by renal and vascular color ultrasonography. Ultrasound Med Biol 2018, 44, 2602–2608.

Journal of Veterinary Research

formerly Bulletin of the Veterinary Institute in Pulawy

Journal Information


IMPACT FACTOR J Vet Res 2018: 0,829
5-year IMPACT FACTOR: 0,938

CiteScore 2018: 0.68

SCImago Journal Rank (SJR) 2018: 0.291
Source Normalized Impact per Paper (SNIP) 2018: 0.501

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 46 46 46
PDF Downloads 41 41 41