A comparative study between four-level NSVM and three-level NSVM technique for a DFIG-based WECSs controlled by indirect vector control

Open access

Abstract

In this work, we present a comparative study between four-level neural space vector modulation (4L-NSVM) and three-level neural space vector modulation (3L-NSVM) technique in indirect vector control (IVC) of reactive and active power control of a doubly fed induction generator (DFIG) for wind energy conversion systems (WECSs). Two controls techniques using IVC-4L-NSVM and IVC-3L-NSVM are proposed and compared. The validity of the proposed control schemes is verified by simulation tests of a DFIG-based wind turbine system (WTSs). The stator active power, stator reactive power and rotor current is determined and compared in the above strategies. The obtained results showed that the proposed IVC with 4L-NSVM technique have reactive and stator active power with low powers ripples and low rotor current harmonic distortion than 3L-NSVM technique.

[1] A. Medjber, A. Moualdia, A. Mellit, M. A. Guessoum, “ Comparative study between direct and indirect vector control applied to a wind turbine equipped with a double-fed asynchronous machine article,” International Journal of Renewable Energy Research, Vol. 3, No. 1, pp. 88-93, 2013.

[2] K. Kerrouche, A. Mezouar, Kh. Belkacem, “Decoupled control of doubly fed induction generator by vector control for wind energy conversion system,” Energy Procedia, Vol. 42, pp. 239-248, 2013.

[3] F. Amrane, A. Chaiba, B. Babas, S. Mekhilef, “ Design and implementation of high performance field oriented control for grid-connected doubly fed induction generator via hysteresis rotor current controller,” Rev. Roum. Sci. Techn.-Electrotechn. Et Energ, Vol. 61, No. 4, pp. 319-324, 2016.

[4] Z. Boudjema, R. Taleb, Y. Djerriri, A. Yahdou, “ A novel direct torque control using second order continuous sliding mode of a doubly fed induction generator for a wind energy conversion system,” Turkish Journal of Electrical Engineering & Computer Sciences, Vol. 25, pp. 965-975, 2017.

[5] Y. Wa, W. Yang, “ Different control strategies on the rotor side converter in DFIG-based wind turbines,” Energy Procedia, Elsevier, Vol. 100, pp. 551-555, 2016.

[6] Y. S. Rao, A. J. Laxmi, “Direct torque control of doubly fed induction generator based wind turbine under voltage dips,” International Journal of Advances in Engineering & Technology, Vol. 3, pp. 711-720, 2012.

[7] S. Massoum, A. Meroufel, A. Massoum, P. Wira, “ A direct power control of the doubly-fed induction generator based on the SVM strategy,” Elektrotehniski Vestnik, Vol. 45, No. 5, pp. 235-240, 2017.

[8] S. M. Tavakoli, M. A. Pourmina, M. R. Zolghadri, “ Comparison between different DPC methods applied to DFIG wind turbines,” International Journal of Renewable Energy Research, Vol. 3, No. 2, pp. 446-452, 2013.

[9] A. Izanlo, S. A. Gholamian, M. V. Kazemi, “Comparative study between two sensorless methods for direct power control of doubly fed induction generator,” Rev. Roum. Sci. Techn.-Electrotechn. Et Energ, Vol. 62, No. 4, pp. 358-364, 2017.

[10] A. Bakouri, H. Mahmoudi, A. Abbou, “ Intelligent control for doubly fed induction generator connected to the electrical network,” International Journal of Power Electronics and Drive System, Vol. 7, No. 3, pp. 688-700, 2016.

[11] M. M. Ismail, A. F. Bendary, “ Protection of DFIG wind turbine using fuzzy logic control,” Alexandria Engineering Journal, Vol. 55, pp. 941-949, 2016.

[12] Z. Boudjema, A. Meroufel, A. Amari, “ Robust control of a doubly fed induction generator (DFIG) fed by a direct AC-AC converter,” Przegląd Elektrotechniczny, Vol. 11, pp. 213-221, 2012.

[13] O. Barambones, J. M. Gonzalez de Durana, “Sliding mode control for power output maximization in a wave energy systems,” Energy Procedia, Vol. 75, pp. 265-270, 2015.

[14] M. El-Azzaoui, H. Mahmoudi, K. Boudaria, “Backstepping control of wind and photovoltaic hybrid renewable energy system,” Internationale Journal of Power Electronics and Drive Systems, Vol. 7, No. 3, pp. 677-686, 2016.

[15] F. Amrane, A. Chaiba, “ A novel direct power control for grid-connected doubly fed induction generator based on hybrid artificial intelligent control with space vector modulation,” Rev. Roum. Sci. Techn.-Electrotechn. Et Energ, Vol. 61, No. 3, pp. 263-268, 2016.

[16] H. Benbouhenni, Z. Boudjema, A. Belaidi, “ Neuro-second order sliding mode control of a DFIG supplied by a two-level NSVM inverter for wind turbine system,” Iranian Journal of Electrical and Electronic Engineering, Vol.14, No. 4, pp. 362-373, 2018.

[17] H. Benbouhenni, Z. Boudjema, A. Belaidi, “ DFIG-based wind turbine system using three-level neural space vector modulation technique,” Majlesi Journal of Mechatronic Systems, Vol. 7, No. 2, 2018.

[18] H. Benbouhenni, A. Moussaoui, Z. Boudjema, “Wind energy conversion systems based on a DFIG controlled by neuro-sliding mode control using NSVM and PWM,” International Conference on Electrical Engineering, December 17-18, 2018, El-oued, Algeria.

[19] M. Hasni, Z. Mancer, S. Mekhtoub, S. Bacha, “Parametric identification of the doubly fed induction machine,” Energy Procedia, Vol. 18, pp. 177-186, 2012.

[20] E. Bounadja, A. Djahbar, Z. Boudjema, “Variable structure control of a doubly fed induction generator for wind energy conversion systems,” Energy Procedia, Vol. 50, pp. 999-1007, 2014.

[21] A. Belkheiri1, S. Aoughellanet, M. Belkheiri, “ FPGA implementation of a space vector pulse width modulation technique for a two-level inverter,” Elektrotehniški Vestnik, Vol. 85, No. 3, pp. 1-7, 2018.

[22] H. Benbouhenni, “ Comparative study between NSVM and FSVM strategy for a DFIG-based wind turbine system controlled by neuro-second order sliding mode,” Majlesi Journal of Mechatronic Systems, Vol. 7, No. 1, 2018.

[23] A. Moosavienia, K. Mohammadi, “A generalized ABFT technique using a fault tolerant neural network,” Iranian Journal of Electrical & Electronic Engineering, Vol. 1, No. 1, pp. 1-10, 2005.

[24] E. Benyoussef, A. Meroufel, S. Barakat, “Three-level DTC based on fuzzy logic and neural network of sensorless DSSM using extende kalman filter,” International Journal of Power Electronics and Drive System, Vol. 5, No. 4, pp. 453-463, 2015.

[25] H. Benbouhenni, Z. Boudjema, A. Belaidi, “ DFIG-based WT system using FPWM inverter,” International Journal Of Smart Grid, Vol. 2, No. 3, pp.142-154, 2018.

[26] H. Benbouhenni, Z. Boudjema, A. Belaidi, “ Using three-level Fuzzy space vector modulation method to improve indirect vector control strategy of a DFIG based wind energy conversion systems,” International Journal Of Smart Grid, Vol.2, No.3, pp.155-171, 2018.

Journal Information

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 209 209 38
PDF Downloads 115 115 11