Data Reduction Method for Synthetic Transmit Aperture Algorithm

Open access

Abstract

Ultrasonic methods of human body internal structures imaging are being continuously enhanced. New algorithms are created to improve certain output parameters. A synthetic aperture method (SA) is an example which allows to display images at higher frame-rate than in case of conventional beam-forming method.

Higher computational complexity is a limitation of SA method and it can prevent from obtaining a desired reconstruction time. This problem can be solved by neglecting a part of data. Obviously it implies a decrease of imaging quality, however a proper data reduction technique would minimize the image degradation.

A proposed way of data reduction can be used with synthetic transmit aperture method (STA) and it bases on an assumption that a signal obtained from any pair of transducers is the same, no matter which transducer transmits and which receives. According to this postulate, nearly a half of the data can be ignored without image quality decrease.

The presented results of simulations and measurements with use of wire and tissue phantom prove that the proposed data reduction technique reduces the amount of data to be processed by half, while maintaining resolution and allowing only a small decrease of SNR and contrast of resulting images.

Behar V., Adam D. (2005), Optimization of sparse synthetic transmit aperture imaging with coded excitation and frequency division, Ultrasonics, 43, 777-788.

Lockwood G. R., Foster F. S. (1996), Optimizing the Radiation Pattern of Sparse Periodic Two-Dimensional Arrays, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., 43, 15-19.

Lockwood G. R., Li P. C., O'Donnell M., Foster F. S. (1996), Optimizing the Radiation Pattern of Sparse Periodic Linear Arrays, IEEE Trans. Ultrason., Ferroelect., Freq. Contr., 43, 7-14.

Nikolov S. I., Jensen J. A. (2000), Application of different spatial sampling patterns for sparse array transducer design, Ultrasonics, 37, 667-671.

Trots I., Nowicki A., Lewandowski M. (2008), Laboratory setup for synthetic aperture ultrasound imaging, Archives of Acoustics, 33, 4, 573-580.

Archives of Acoustics

The Journal of Institute of Fundamental Technological of Polish Academy of Sciences

Journal Information


IMPACT FACTOR 2016: 0.816
5-year IMPACT FACTOR: 0.835

CiteScore 2016: 1.15

SCImago Journal Rank (SJR) 2016: 0.432
Source Normalized Impact per Paper (SNIP) 2016: 0.948

Metrics

All Time Past Year Past 30 Days
Abstract Views 0 0 0
Full Text Views 125 77 21
PDF Downloads 50 37 8